OM-PE E V1.08
August 24, 2015
Page 10
PE1006
This appliance must be connected to a listed high temperature
(ULC629 IN CANADA OR
UL-103HT IN THE USA)
residential type factory built solid fuel chimney or an approved
masonry chimney with a fl ue liner.
Chimney and chimney connector must be in good condition and kept clean.
NEVER vent the stove to other rooms of the building. Must be vented to the outside ONLY.
NEVER use a chimney or chimney connector smaller then the stove exhaust, unless
approved by your local inspector.
NEVER vent the stove into a “Class B” gas vent chimney.
DO NOT CONNECT IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
Inspect the chimney connector and chimney regularly during each burning season and
clean when necessary.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
NEVER intentionally start a chimney fi re to clean the fl ue.
When installed in a mobile home, this appliance must be bolted to the fl oor and provided
with outside air.
WARNING: DO NOT INSTALL IN A SLEEPING ROOM
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME
FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
Check with local building offi cials.
If the Optional Fan Kit is
installed, connect this unit to
a properly grounded, 110-volt
electrical outlet. Do not route
the power cord in front of or
under the stove.
Do not make any changes or
modifi cations to an existing
masonry fi replace or chimney
to install this appliance. Do
not make any changes to
the appliance to increase
combustion air.
SAFETY PRECAUTIONS
IF THIS BLAZE KING STOVE IS NOT PROPERLY INSTALLED OR OPERATED, A HOUSE FIRE MAY
RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE
TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
Summary of Contents for KING KE1107
Page 49: ...OM PE E V1 08 August 24 2015 Page 49 PE1006 REPLACEMENT PARTS cont REPLACEMENT PARTS cont ...
Page 50: ...OM PE E V1 08 August 24 2015 Page 50 PE1006 REPLACEMENT PARTS cont ...
Page 57: ...OM PE E V1 08 August 24 2015 Page 57 PE1006 NOTES ...
Page 58: ...OM PE E V1 08 August 24 2015 Page 58 PE1006 NOTES ...
Page 59: ...OM PE E V1 08 August 24 2015 Page 59 PE1006 NOTES ...