12.1 Cable connections
Main connector (D15HD connector: Unit Female, Cable Male)
12.2 Connection Diagram
The use of an external 1A fuse is recommended. Connect the supply terminals to your aircrafts power supply. Ensure that
the supply voltage will not drop below 8V during operation as this may result in incorrect readings.
D15HD Pin
Color
Function
1
Red
8-30Vdc power via power switch / circuit breaker
and fuse.
2
Black
Ground
3
-
RS232 Transmit data (Firmware upgrading)
4
White/Black
Stripe
RS232 Receive data (Firmware upgrading /
NMEA GPS Input)
12
Purple
CAN Low
13
Pink
CAN High
15
White
Alarm Output (Open collector)