70
[1.4 MOTOR CONTROL]
(drC-)
Selecting the encoder
Follow the recommendations in the catalog and the Installation Manual.
(1) The encoder parameters can only be accessed if the encoder card has been inserted, and the available selections will depend
on the type of encoder card used. The encoder configuration can also be accessed in the
[1.5- INPUTS / OUTPUTS CFG]
(I/O)
menu.
Code
Name/Description
Adjustment range
Factory setting
EnS
• [Encoder type]
[AABB]
(AAbb)
nO
AAbb
Ab
A
To be configured in accordance with the type of card and encoder used (1).
-
[----]
(nO)
: Card missing.
-
[AABB]
(AAbb)
: For signals A, A-, B, B-.
-
[AB]
(Ab)
: For signals A, B.
-
[A]
(A)
: For signal A. Value cannot be accessed if
[Encoder usage]
(EnU)
page
71
=
[Spd fdk reg.]
(rEG).
PGI
• [Number of pulses]
100 to 5,000
1,024
Number of pulses per encoder revolution.
The parameter can be accessed if an encoder card has been inserted (1).
Summary of Contents for ER40-G
Page 2: ......
Page 21: ...21 The display flashes to indicate the presence of a fault ...