background image

 
 

16

If You Use a TopTier

tm

 Brewing Stand: 

 
Blichmann Engineering

tm

 offers a utility shelf (10” X 10”) that readily supports two controllers.  We also offer a 

TopTier

tm

 installation kit for installing your Tower permanently to the stand.  See fig 14 on page 9.  

 

 

Controller Operation

 

 

The TOWER of POWER

tm

 controller uses a digital PID temperature controller to maintain the set temperature 

of the liquid returning to the TOP of your mash. Again, it is VITAL that you do NOT put the sensor directly 

into the mash.  For your HLT it is recommended to install it directly into your tank.   
 
When heat is needed, the controller simultaneously activates an ignition sequence (sparking on the electrode), 

turns on the gas flow by opening the gas solenoid valve, and activates an alarm horn letting you know the 
burner is about to ignite.   
 

When a flame is established, the ignition system detects a change in resistance in the lead wire and turns off 
the sparking, but leaves the gas valve open.  If the flame is lost (eg, a gust of wind) it will automatically 
reactivate the spark to reignite the flame. If at any time a flame cannot be established within 10 sec it will 

stop the ignition trial and will sound an alarm horn. 
 

Warning!

 Always make sure that your pot is filled with sufficient liquid before turning on your controller. 

Adding heat to an empty pot will cause permanent damage! 
 

Warning!

 If you are unable to ignite after 10 sec turn the selector switch to RESET immediately.  This will 

deactivate the gas valve and ignition sequence.  Check fuel tank level, and that all gas valves and regulators 
are on. Check that the solenoid valve is installed in the correct direction, and that the ignition and ground 

wires are properly installed. At this time you can return the selector switch back to AUTO mode.  

 
Note:

 you need to have the selector switch in RESET mode for at least 3 sec to reset the ignition controller. 

 

Changing Temperature Setting:

 Refer to Fig 30.  ACT 

will display the sensor temperature.  SET will display 
your desired temperature.  Press the up and down arrows 
to increase or decrease the temperature. Leaving the 

button depressed will increase/decrease the temperature 
rapidly.  While changing the SET temperature, the SET 
temp display will flash.  When you have reached your 

desired temperature depress the enter button to accept 
the value and the SET value will stop flashing. 
 

Important:

 if the SET value is flashing it is NOT 

activated.  Always press the enter button after changing 
the SET point. 

 

Changing Units F/C

 – see appendix at the end of this manual 

 

Selector Switch Modes

 (ref fig 30) 

 

 

 

AUTO

 – Use this position to let the PID controller automatically turn your burner on/off  

RESET

 – Use to reset the ignition system if you are unable to generate a flame within10 sec.  (3 sec 

reset) This mode can also be used to disable the flame/ignitor if desired.           

MANUAL

 – Use this mode to override the PID controller and turn on the flame to add heat. 

 

 

 

 

   

Fig. 30 

Summary of Contents for TOWER of POWER

Page 1: ...ead and understood these instructions Caution Sections labeled Caution can lead to equipment damage or unsatisfactory performance of the equipment Please read these sections thoroughly If you have any questions contact your retailer or Blichmann Engineering www BlichmannEngineering com before use Important Sections labeled Important are critical to the proper performance and life of the product Se...

Page 2: ...ey can purchase the Tower module that provides all the needed plumbing and provides a convenient stand for the control module s If you already own a March 809 815 pump you can purchase the Tower without the pump Note the hoses that connect from the Tower to the pots are not included If you are a TopTiertm owner an optional mounting kit is available to mount it permanently to the stand Controller M...

Page 3: ... Flow GPM LPM 5 19 0 5 2 8 10 38 0 75 3 8 15 57 1 25 4 75 20 76 1 5 5 7 32 121 2 25 8 5 Important Grain bed flow rates are highly dependent on crush quality Move to a coarser crush if you are not able to flow at the above rates It is also recommended that you allow a 10 min dough in prior to turning on the pump to allow the air to purge from the grain and for the grain to fully absorb the water Bu...

Page 4: ...itions above with your system that is OK but it must be expected that stability and control will be compromised Note A slight overshoot of the recirculation temperature is normal and will NOT harm your enzymes Enzymes are denatured over a period of time not instantaneously We have tuned this system to offer the best match of ramp speed and stability The chart below shows a typical response curve f...

Page 5: ...out sticking your mash Note that rice hulls can aid in increasing recirculation rates Assembly The TOWER of POWERtm Modular Brewing Control ships partially assembled to allow it to be shipped more economically via ground carriers and to protect it from shipping damage Parts List The following items are shipped with the product Please check to verify that you received all the parts Contact your RET...

Page 6: ...mp March 815 if ordered with Tower Optional Dual Controller Mounting Plate reqd for mounting two controllers onto the tower 1 Plate model aCon_plate_TOP 4 10 24 X 3 8 long pan head screws Assembling the Tower Prepare a work area with a soft pad to protect the tower enclosure from getting scratched during assembly WARNING Make sure that the tower is NOT plugged in until you have fully completed the...

Page 7: ...ump head to so that the inlet faces down and the outlet faces up flow arrow faces up Simply remove the 4 mounting screws rotate the head and reinstall the pump head Consult the March manual if needed To wire the pump insert the pump lead wire through the rubber grommet in the back of the enclosure and feed it out the bottom of the enclosure Fig 6 Fig 3 Fig 4 Fig 5 Fig 6 Drip Shield Fig 7 Fig 8 Pla...

Page 8: ...s that are labeled pump power and connect them to the matching color leads on the pump lead using the wire nuts as shown in Fig 8 Then push the remaining wire up into the bottom of the tower Install the pump hose between the pump and the bottom of the flow meter as shown in Fig 9 Install the 90 degree QuickConnector onto the bottom of the pump Fig 10 Install the 3 8 90 degree QuickConnector onto t...

Page 9: ...wn in Fig 13 using the outer most 4 screw holes Then use an additional 4 screws to mount the assembly onto the tower as shown in Fig 12 using the inner 4 screw holes and placing the screws through the mating holes in the angle brackets on the top of the Tower Plug each controller into the GFCI receptacle on the back of the tower WARNING Make sure that the tower is NOT plugged in until you have ful...

Page 10: ...at or moisture If it is warm to the touch it is too close to heat source NEVER HEAT COOKING OIL WITH THIS EQUIPMENT NEVER operate on soft combustible or uneven surfaces like dirt gravel wood or asphalt NEVER operate indoors in a garage under an overhang porch deck carport or similar structure NEVER use near and combustible chemicals gasoline or other flammable vapors or liquids NEVER Bypass the GF...

Page 11: ... or gas valve off at the source when not in use Fig 16 and 17 show typical installations Important The brass orifice fitting small hole through it supplied with your burner must ALWAYS be installed directly on the burner casting Do NOT install this fitting on the inlet to the regulator or your burner will not function properly Install the ignition electrode The ignition electrode is used to create...

Page 12: ...are not to crack the insulator Cracked electrodes are not covered under warranty Trim the wire using a wire cutter to the length noted previously Install the electrode and note the position of tip of the wire with respect to the surface of the burner Trim as needed to provide a 3 16 1 4 gap It is OK to bend the wire a bit as needed to center the tip of the electrode Fig 18 and 19 show typical inst...

Page 13: ...emale NPT fitting place the o ring washer and adapter bushing onto the sensor as shown in Fig 22 Place 4 5 turns of quality Teflon tape not included to the external NPT threads of the bushing Do not use tape on the sensor threads Then thread the assembly into the fitting Caution Once installed the bushing CANNOT be removed DO NOT over tighten Use a wrench to tighten the sensor and thread it into t...

Page 14: ...r mash tun to the inlet of the pump Install a flow control valve after the pump Then plumb through the sensor and lastly back to the TOP of the mash bed Note it is also acceptable to switch the order of the flow control valve and the sensor Installing the sensor in your own system locate the sensor according to the schematic in Fig 25 A close up of the sensor installed in a pipe T not included but...

Page 15: ...this power will cause permanent damage to the ignition system and is not covered under warranty Never exceed 30 PSI on the solenoid valve Warning The ignition system uses high voltage to create a spark Do not power up the controller and leave the selector switch in Reset mode until connections of the ground and ignition wires are made or shock could occur ALWAYS place the black vinyl cover over th...

Page 16: ...ning If you are unable to ignite after 10 sec turn the selector switch to RESET immediately This will deactivate the gas valve and ignition sequence Check fuel tank level and that all gas valves and regulators are on Check that the solenoid valve is installed in the correct direction and that the ignition and ground wires are properly installed At this time you can return the selector switch back ...

Page 17: ... the flow meter is equipped with a low flow switch and alarm horn that will notify you in advance that your flow is dropping and your mash is beginning to stick Simply slide the switch assembly up or down to the desired low flow setting Important It is possible for bits of grain to become lodged in the valve or in the flow meter This may give a false indication that the mash is sticking Simply ope...

Page 18: ...djust the flow to your desired setting using the handle on the 3 way valve or your flow control valve to throttle it back if needed NEVER throttle the flow to the INLET of the pump ALWAYS on the OUTLET of the pump 5 Place all controller mode selector switches to RESET 6 Turn on the controllers and enter the desired strike water and HLT temperature into the controller 7 Place both controllers in AU...

Page 19: ... need to be sanitized it DOES need to be clean We recommend recirculating PBW Powdered Brewery Wash and then StarSan through your system immediately after each use Simply use a bottling bucket filled with PBW elevate it above your pump and connect with a hose to the inlet of the pump Place the outlet hose return hose to your mash tun in the top of the bucket Open the valves and start the pump If u...

Page 20: ...ons and your fastest way to resolve your issues if the chart below does not resolve your problem Your retailer will contact Blichmann Engineering if they are unable to resolve your issues Display flashing Press enter key to accept temperature setting If flashing does not stop cycle power on front of controller If this recurs contact your retailer Overshoot Increase flow and or decrease heat input ...

Page 21: ... are open Check that mash is not stuck compacted See below Check that all hoses downstream of the pump are empty Install a bleed valve after the pump to vent air and allow the pump to fill with liquid For Tower users the sample port can be used Mash is sticking Reduce flow rate Ensure you have done a dough in WITHOUT the pump on to allow air to purge from the grain bed Check that grain crush is no...

Page 22: ... will be the responsibility of the customer Resolution of warranty claims will be by repair or replacement and will be the decision solely of Blichmann Engineeringtm Shipping costs for warrantee returns are covered only for the contiguous United States User is responsible for packaging costs and shipping damage if not returned in original packing Approval for return must be provided by Blichmann E...

Reviews: