7
Install the pump bracket using the 5/16” bolts as shown in Fig. 4. Then using the ¼-20 X ½” bolts, nuts and
washers, install the drip shield and pump as shown in Fig. 5.
Important:
Referencing Fig. 7, it may be necessary to re-orient the pump head to so that the inlet faces down
and the outlet faces up (flow arrow faces up). Simply remove the 4 mounting screws, rotate the head, and
reinstall the pump head. Consult the March manual if needed.
To wire the pump, insert the pump lead wire through the rubber grommet in the back of the enclosure and
feed it out the bottom of the enclosure (Fig. 6).
Fig 3
Fig 4
Fig 5
Fig 6
Drip Shield
Fig 7
Fig 8
Place pump wire
through grommet