10
CONTROLLER SCREEN OPERATION
OFF/AUTO/ON
- Cycle through power options.
ACTUAL TEMPERATURE
- Displays the sensor temperature value.
NOTE:
If the temperature is beyond the “out of range” value (programmable in basic settings) the text color will change. Blue is below (too cold), black is in
the desired range, and red is above the range (too hot).
SET TEMP
- This is the desired temperature. Pressing this value will display a numerical keypad. Enter the desired value and press ENTER to accept.
TIMER
- This value displays the remaining time of the active timer. This value can’t be changed from the home screen.
OFF/AUTO/ON
- Press button to cycle through the options below.
OFF
- Power to the burners is disabled.
AUTO
- The burner will automatically light as needed to maintain the desired SET temperature.
ON
- The burner will turn on and continually run. This setting overrides the automatic control. The SET value will change to BOIL.
PUMP
- Turns the auxiliary 120V receptacle located on the back of the unit on and off. Green illuminated button indicates that the power is in the ON mode.
MENU
- Pressing this button will open the main menu screen.
PUMP
- ON/OFF.
HOME SCREEN
MENU SCREEN
MENU
- Main Menu.
SET
- Change the set temperature.
TIMER
- Displays active timer.
ACTUAL TEMPERATURE
MASH
- Mash Profile.
BOIL
- Boil Profile.
TIMER
- Set a timer.
HOME
- Return to the HOME
Screen.
SETTINGS
= Interactive
= Active Button
= Inactive Button
SCREEN CONVENTIONS
Firmware Version: Ver 1.1:1.2