FOR REFERENCE ONLY
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
02h
CAN Object 2002h
Byte 2
20h
Byte 3
XXh
XX: Sub index
01h: Red Led
02h: Green Led
03h: Blue Led
Byte 4,7
00h
Not used
Examples:
Direction
Identifier Format Message
Data
To Keypad
615
Std
40 02 20 01 00 00 00 00
Read red LED blink
Keypad reply
595
Std
4F 02 20 01 FF 00 00 00
All red LED blink
To Keypad
615
Std
40 02 20 02 00 00 00 00
Read green LED blink
Keypad reply
595
Std
4F 02 20 02 01 00 00 00
Only green LED #1
blinks
To Keypad
615
Std
40 02 20 03 00 00 00 00
Read blue LED blink
Keypad reply
595
Std
4F 02 20 03 00 00 00 00
No blue LED blinks
17.
Object 2003h: Brightness Level
a)
Set Indicator LED brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
01h
Sub index
Byte 4
YYh
Intensity 00h-3Fh
à
min-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 01 0D 00 00 00
Brightness = 25%
Keypad reply
595
Std
60 03 20 01 00 00 00 00
b)
Backlight brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
02h
Sub index