FO
R
REFE
RE
NC
E O
N
LY
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - info@blinkgroup.com
Example:
Example:
13
16. OBJECT 2010H: BAUD RATE SETTING
17. OBJECT 2011H: SET BOOT-UP SERVICE
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 10 20 00 03 00 00 00
Baud rate = 250k
Keypad Reply
595
Std
60 10 20 00 00 00 00 00
Object 2011h message enable or disable the boot up message sent by the keypad at power up to
the CAN network.
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 11 20 00 00 00 00 00
Boot-up service not
active
Keypad Reply
595
Std
60 11 20 00 00 00 00 00
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
10h
CAN Object 2010h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
00h
1000k
01h
Reserved (force to 125k)
02h
500k
03h
250K
04h
125k (Default)
05h
Reserved (force to 125k)
06h
50k
07h
20k
Byte 5,7
00h
Not used
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
11h
CAN Object 2011h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Not active
01h: Active
Byte 5,7
00h
Not used