PKP2500SI_CANopenUM_REV1.0
24/38
28.
Object 1000h: Device Type
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
00h
CAN Object 1000h
Byte 2
10h
Byte 3, 7
00h
Not used
Example:
Direction
Identifier
Format
Data
To Keypad
615
Std
40 00 10 00 00 00 00 00
Keypad reply
595
Std
43 00 10 00 91 01 0B 00
Device profile number 0xB0191h.
29.
Object 1001h: Error Register
This object is not yet implemented in the device.
30.
Object 1008h: Manufacturer Device Name
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
08h
CAN Object 1008h
Byte 2
10h
Byte 3, 7
00h
Not used
1° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
60h
Read Device Register Next Byte
Byte 1, 7
00h
Not used
2° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
70h
Read Device Register Next Byte
Byte 1, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 08 10 00 00 00 00 00
Keypad reply
595
Std
41 08 10 00 0B 00 00 00
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad reply
595
Std
00 42 6C 69 6E 6B 4D 61
BlinkMa
To Keypad
615
Std
70 00 00 00 00 00 00 00
Keypad reply
595
Std
17 72 69 6E 65 00 00 00
rine
Manufacturer Device Name: BlinkMarine
The first byte of the last data message replied is 17h.