19/28
PKP2600SI_CANopenUM_REV1.1
31.Object 100Bh: Model ID
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
0Bh
CAN Object 100Bh
Byte 2
10h
Byte 3, 7
00h
Not used
1° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
60h
Read Device Register second byte
Byte 1, 7
00h
Not used
2° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
70h
Read Device Register third byte
Byte 1, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 0B 10 00 00 00 00 00
Keypad Reply
595
Std
41 0B 10 00 09 00 00 00
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad Reply
595
Std
00 50 4B 50 32 36 30 30
PKP2600
To Keypad
615
Std
70 00 00 00 00 00 00 00
Keypad Reply
595
Std
1B 53 49 00 00 00 00 00
SI
Model ID: PKP2600SI
The first byte of the last data message replied is 1Bh.