25/28
PKP2600SI_CANopenUM_REV1.1
b)
Set periodic state transmission
Identifier 600h + current CAN ID
Default 615h
Byte 0
2Bh
Set device register
Byte 1
00h
CAN Object 1800h
Byte 2
18h
Byte 3
05h
Sub index
Byte 4
YYh
YYh: Event timer period in milliseconds LSByte
Byte 5
XXh
XXh: Event timer period in milliseconds
MSbyte
Byte 6, 7 00h
Not used
Event timer period: XXYYh (from 0A00h to FFFEh: 10ms to 65534 milliseconds).
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2B 00 18 05 00 00 00 00
Switch off the periodic
state transmission
Keypad Reply
595
Std
60 00 18 05 00 00 00 00
To Keypad
615
Std
2B 00 18 05 32 00 00 00
Set period = 50ms
Keypad Reply
595
Std
60 00 18 05 00 00 00 00
To Keypad
615
Std
2B 00 18 05 F4 01 00 00
Set period = 500ms
Keypad Reply
595
Std
60
0 18 05 00 00 00
00
42.Object 1A00h Transmit PDO Mapping Parameter
Describes the mapping of Key state PDO Message.
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
00h
CAN Object 1A00h
Byte 2
1Ah
Byte 3
00h
Number of mapped objects
01h
PDO Mapping Entry 1
Byte 4,7
00h
Not used
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 00 1A 00 00 00 00 00
Keypad Reply
595
Std
4F 00 1A 00 01 00 00 00
1
To Keypad
615
Std
40 00 1A 01 00 00 00 00
Keypad Reply
595
Std
43 00 1A 01 10 01 00 20
2000 01 10
Transmit PDO Mapping Parameter:
•
Number of mapped objects: 1;
•
Switch state: Object 2000h, Sub index 01h, Length 10h;