Example:
Example:
Example:
i) Set default startup LEDlight level: 7Ch
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
00h
CAN Object 6500h
Byte 2
65h
Byte 3
01h
Sub index
Byte 4
7Ch
Command: Set startup LED level
Byte 5
XXh
0-3Fh
-
0-100%
Byte 6,7
00h
Not used
Direction
Identifier
Format
Data
To Keypad
615
Std
23 00 65 01 7C 3F 00 00
100%
Keypad Reply
595
Std
60 00 65 01 00 00 00 00
j) Set default startup backlight level: 7Bh
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
00h
CAN Object 6500h
Byte 2
65h
Byte 3
01h
Sub index
Byte 4
7Bh
Command: Set backlight level
Byte 5
XXh
0-3Fh
-
0-100%
Byte 6,7
00h
Not used
Direction
Identifier
Format Message
Message
Data
To Keypad
615
Std
23 00 65 01 7B 00 00 00
Backlight = 0% at startup
Keypad Reply
595
Std
60 00 65 01 00 00 00 00
k) Set DEMO mode: 7Ah
Demo mode is a special feature that consist in different LED states for each button pressing.
Disconnect and reconnect the keypad to enter this mode.
Identifier
615h (600h + current CAN ID)
Byte 0
23h
Set Device Register
Byte 1
00h
CAN Object 6500h
Byte 2
65h
Byte 3
01h
Sub index
Byte 4
7Ah
Command: Set DEMO mode
Byte 5
XXh
01h : on
00h: off
Byte 6,7
00h
Not used
Direction
Identifier
Format Message
Data
To Keypad
615
Std
23 00 65 01 7A 01 00 00
Set demo mode on
Keypad Reply
595
Std
60 00 65 01 00 00 00 00
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - info@blinkgroup.com
14
FOR REFERENCE ON
LY