15. OBJECT 6001H: DIGITAL OUTPUT MODULE.
This module sets and reads the LED Outputs States. A one indicates the LED is on a zero indicates the
LED is off.
a) Set LED ON
•
PKP 2200
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
01h
CAN Object 6001h
Byte 2
60h
Byte 3
00h
Sub index
Byte 4
XYh
X: G4 G3 G2 G1 Green LED
Y: R4 R3 R2 R1 Red LED
Byte 5,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
23 01 60 00 00 00 00 00
Set all LED off
Keypad Reply
595
Std
60 01 60 00 00 00 00 00
To Keypad
615
Std
23 01 60 00 80 00 00 00
Set green LED #4 on
Keypad Reply
595
Std
60 01 60 00 00 00 00 00
To Keypad
615
Std
23 01 60 00 04 00 00 00
Set red LED #3 on
Keypad Reply
595
Std
60 01 60 00 00 00 00 00
•
PKP 2400
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
01h
CAN Object 6001h
Byte 2
60h
Byte 3
00h
Sub index
Byte 4
XXh
R8 R7 R6 R5 R4 R3 R2 R1 Red LED
Byte 5
YYh
G8 G7 G6 G5 G4 G3 G2 G1 Green LED
Byte 6,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
23 01 60 00 00 00 00 00
Set all LED off
Keypad Reply
595
Std
60 01 60 00 00 00 00 00
To Keypad
615
Std
23 01 60 00 00 01 00 00
Set green LED #1 on
Keypad Reply
595
Std
60 01 60 00 00 00 00 00
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - info@blinkgroup.com
18
FOR REFERENCE ON
LY
Example:
Example: