16. OBJECT 6002H: DIGITAL OUTPUT MODULE.
This module sets and reads the LED Blink States.
Each bit position represents the corresponding LED. A one indicates the LED is Blinking a zero indicates
the LED is Normal. If the Blink Bit is active with the ON Bit Active the LED will Blink Inverse to Normal
Operation (ALT blink).
a) Set LED blink
•
PKP 2200
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
02h
CAN Object 6002h
Byte 2
60h
Byte 3
00h
Sub index
Byte 4
XYh
X: G4 G3 G2 G1 Green LED
Y: R4 R3 R2 R1 Red LED
Byte 5,7
Not Used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
23 02 60 00 00 00 00 00
No LED blinks
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
To Keypad
615
Std
23 02 60 00 08 00 00 00
Only red LED #4 blinks
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
To Keypad
615
Std
23 02 60 00 10 00 00 00
Only green LED #1
blinks
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
•
PKP 2400
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
02h
CAN Object 6002h
Byte 2
60h
Byte 3
00h
Sub index
Byte 4
XXh
R8 R7 R6 R5 R4 R3 R2 R1 Red LED
Byte 5
YYh
G8 G7 G6 G5 G4 G3 G2 G1 Green LED
Byte 6,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
23 02 60 00 00 00 00 00
No LED blinks
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
To Keypad
615
Std
23 02 60 00 01 00 00 00
Only red LED #1 blinks
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
To Keypad
615
Std
23 02 60 00 00 FF 00 00
All green LED blink, red
LED do not blink
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - info@blinkgroup.com
21
FOR REFERENCE ON
LY
Example:
Example: