Example:
20. OBJECT 1009H: MANUFACTURER HARDWARE REVISION
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
09h
CAN Object 1009h
Byte 2
10h
Byte 3, 7
00h
Not used
1° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
60h
Read Device Register second byte
Byte 1, 7
00h
Not used
2° additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
70h
Read Device Register third byte
Byte 1, 7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 09 10 00 00 00 00 00
Keypad Reply
595
Std
41 09 10 00 0A 00 00 00
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad Reply
595
Std
00 52 65 76 20 31 2E 30
Rev 1.0D
To Keypad
615
Std
70 00 00 00 00 00 00 00
Keypad Reply
595
Std
19 00 44 00 00 00 00 00
Manufacturer Hardware Revision: Rev 1.0D
The first byte of the last data message replied is 19h.
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - info@blinkgroup.com
26
FOR REFERENCE ON
LY