Example:
Example:
Example:
Example:
Example:
Example:
d. Revision Number
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
18h
CAN Object 1018h
Byte 2
10h
Byte 3
03h
Sub index
Byte 4,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 18 10 03 00 00 00 00
Keypad Reply
595
Std
43 18 10 03 10 16 12 00
00 10 15 10
Byte 0 App Revision
Byte 1 Com Lib Rev
Byte 2 HW Lib Rev
Revision Number: App revision 10h, Com lib revision 16h, HW lib revision 12h.
e. Firmware checksum
Identifier
600h + current CAN ID
Byte 0
40h
Read Device Register
Byte 1
18h
CAN Object 1018h
Byte 2
18h
Byte 3
04h
Sub index
Byte 4,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 18 10 04 00 00 00 00
Keypad Reply
595
Std
43 18 10 04 DE E5 2C 00
00 2C E5 DEh
Firmware checksum: 00 2C E5 DEh