33. OBJECT 6302H: DEVICE KEY AND LED COUNT
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
02h
CAN Object 6302h
Byte 2
63h
Byte 3
XXh
00h: Number of objects
01h: Total number of Keys
02h: Number of external Keys
03h: Total number of LED
04h: Number of external LED
Byte 4,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 02 63 00 00 00 00 00
Keypad Reply
595
Std
4F 02 63 00 02 00 00 00
2
To Keypad
615
Std
40 02 63 01 00 00 00 00
Keypad Reply
595
Std
4F 02 63 01 0F 00 00 00
0Fh
To Keypad
615
Std
40 02 63 02 00 00 00 00
Keypad Reply
595
Std
4F 02 63 02 03 00 00 00
3h
To Keypad
615
Std
40 02 63 03 00 00 00 00
Keypad Reply
595
Std
4F 02 63 03 1E 00 00 00
1Eh
To Keypad
615
Std
40 02 63 04 00 00 00 00
Keypad Reply
595
Std
4F 02 63 04 06 00 00 00
06h
PKP2600 key and LED count: Number of objects: 2; Total number of keys: 15;
Number of external keys: 3; Number of LED: 30;
Number of external LED: 6.