PowerTrackCANopenUM_REV1.4
26/31
d)
Set blue LEDs backlight brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
04h
Sub index
Byte 4
XXh
Intensity 00h-3Fh
0-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 04 04 00 00 00
Brightness = 25%
Keypad Reply
595
Std
60 03 20 04 00 00 00 00
e)
Set startup Indicator LEDs brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
05h
Sub index
Byte 4
XXh
Intensity 00h-3Fh
0-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 03 10 00 00 00
Brightness = 25%
Keypad Reply
595
Std
60 03 20 03 00 00 00 00
f)
Set startup green LEDs backlight brightness level
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
06h
Sub index
Byte 4
XXh
Intensity 00h-3Fh
0-100%
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 03 20 06 10 00 00 00
Brightness = 25%
Keypad Reply
595
Std
60 03 20 06 00 00 00 00