Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 25 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
info@blinkgroup.com
PKP-2200-SI_CANopenUM_REV1.0
35.
Object 1400h: Receive PDO Communication Parm 0
Describes the Receive Parameters and sets the transmission type for the LED state PDO Message.
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
2Fh
Set Device Register
Byte 1
00h
CAN Object 1400h
Byte 2
14h
Byte 3
00h
Number of mapped objects
01h
COB Id
02h
Transmission Type
Byte 4
XXh
Transmission Type (to be used only in set mode):
00h-F0h: synchronous
FEh: event-driven
Byte 5,7
00h
Not used
Examples:
Direction
Identifier Format Message
Data
To Keypad
615
Std
40 00 14 00 00 00 00 00
Keypad reply
595
Std
4F 00 14 00 02 00 00 00
2
To Keypad
615
Std
40 00 14 01 00 00 00 00
Keypad reply
595
Std
43 00 14 01 15 02 00 00
0000 0215h
To Keypad
615
Std
40 00 14 02 00 00 00 00
Keypad reply
595
Std
4F 00 14 02 FE 00 00 00
FEh
To Keypad
615
Std
2F 00 14 02 01 00 00 00
Set Synchronous RPDO 0
Keypad reply
595
Std
60 00 14 02 00 00 00 00 ACK
To Keypad
80
Std
-
SYNC message received
To Keypad
215
Std
01 00 00 00 00 00 00 00
Request LED 1 red ON: the
data are buffered
To Keypad
80
Std
-
SYNC message received and
message 215 processed
Receive PDO communication Parm 0:
•
Number of mapped objects: 2;
•
COB id: 0000 0200h + NODE ID;
•
Transmission Type: synchronous or event-driven.