background image

023801

CCS_SECC_ResponseCode_FAILED_CPS_SubCA1_
CertificateRevoked

023802

CCS_SECC_ResponseCode_FAILED_CPS_SubCA2_
CertificateRevoked

023803

CCS_SECC_ResponseCode_FAILED_CPS_RootCA_
CertificateRevoked

023804

CCS_SECC_ResponseCode_FAILED_reserved_1

023805

CCS_SECC_ResponseCode_FAILED_reserved_2

023806

CCS_SECC_ResponseCode_FAILED_reserved_3

023807

CCS_SECC_ResponseCode_FAILED_reserved_4

023808

CCS_SECC_ResponseCode_FAILED_reserved_5

023809

CCS_SECC_TIMEOUT_SLAC_TT_EVSE_SLAC_init

023810

CCS_SECC_TIMEOUT_SLAC_TP_match_response

023811

CCS_SECC_TIMEOUT_CM_START_ATTEN_CHAR_IND

023812

CCS_SECC_TIMEOUT_SLAC_TT_EVSE_match_MNBC

023813

CCS_SECC_TIMEOUT_SLAC_TP_EVSE_avg_atten_calc

023814

CCS_SECC_TIMEOUT_SLAC_CM_ATTEN_CHAR_RSP

023815

CCS_SECC_TIMEOUT_SLAC_CM_VALIDATE_REQ_1ST__CM_SLAC_
MATCH_REQ

023816

CCS_SECC_TIMEOUT_SLAC_TT_EVSE_assoc_session

023817

CCS_SECC_TIMEOUT_SLAC_TT_EVSE_vald_toggle

023818

CCS_SECC_TIMEOUT_SLAC_CM_MNBC_SOUND_IND

023819

CCS_SECC_TIMEOUT_SLAC_CM_VALIDATE_REQ_2ND__CM_SLAC_
MATCH_REQ

023820

CCS_SECC_TIMEOUT_SLAC_reserved_3

023821

CCS_SECC_TIMEOUT_SLAC_reserved_4

023822

CCS_SECC_TIMEOUT_SLAC_reserved_5

023823

CCS_SECC_TIMEOUT_SLACC_SDP_UDP_TT_match_join

023824

CCS_SECC_TIMEOUT_SLACC_SDP_TCP_TT_match_join

023825

CCS_SECC_TIMEOUT_SLACC_SDP_TP_amp_map_exchange

023826

CCS_SECC_TIMEOUT_SLACC_SDP_TP_link_ready_notification

023827

CCS_SECC_TIMEOUT_SLACC_SDP_reserved_1

023828

CCS_SECC_TIMEOUT_SLACC_SDP_reserved_2

Status Code

Description

43

semaconnect.com

Summary of Contents for SemaConnect DDWx362 Series

Page 1: ...r Dispenser User Manual Installation Instructions Copyright 2021 reserves the right to update the manual without any notice The customized appearance is subject to the customer s description A Blink Charging Company ...

Page 2: ... 2 Grounding and Safety Requirements 11 3 3 Unpack the charger 13 3 4 Recommended Tools for Installation and Inspection 16 3 5 Installation Procedure 18 3 6 Installation Inspection Commissioning 24 Screw torque requirement table 26 4 Operation Process 27 4 1 Operating Sequence 27 4 2 Operating Procedure 27 4 3 Troubleshooting 33 4 4 Status Codes 33 5 Maintenance 54 5 1 General Maintenance 54 5 2 R...

Page 3: ...Revision Date Description Author DDWx362 SeriesPH RW_V0 1 2021 07 12 UL First Issue Monique DDWx362 SeriesPH RW_V0 2 2021 10 13 concrete base modified Monique Revision History semaconnect com ...

Page 4: ...formation The Power Dispenser Fast Char ger has a clear user interface with function buttons safety certifications and an excellent waterproof and dust proof design to provide the best choice for outdoor environments Features Pluggable power modules make installation easy and flexible Offers customers the convenience of start stop charging control from an autho rized RFID smart card or mobile APP ...

Page 5: ... home Right Button select RFID Card Reader Charging Process Charging Status Alarm Emergency Stop Left Charging Connector Right Charging Connector Left LED Indicator The charging connectors installed on the EVSE may vary depending on the designated application 2 semaconnect com ...

Page 6: ... 25 50 75 100 of 360kW Voltage Accuracy 2 Current Accuracy 2 DC Input Power Cable Please refer to the P 13 14 of power cabinet user manual DC Output Output Voltage Range CCS1 CCS2 150Vdc 950Vdc CHAdeMO 150Vdc 500Vdc Maximum Output Current Liquid Cooling CCS1 CCS2 500A 150Vdc 720Vdc when output voltage up to 950Vdc the output current is 380A Natural Cooling CCS1 CCS2 Combo Single output mode 200A 1...

Page 7: ...DC contactor detection User Interface Control Display 7 inch LCD User Authentication RFID Support ISO 14443A B ISO 15693 FeliCa Lite S RCS966 OCPP APP Mobile Payment Backend Support Please refer to the user manual of cabinet Environmental Conditions Operation Temperature 30 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 5 95 RH non condensing Altitude 2000m 6561 Regulations Safety UL...

Page 8: ... Weight typ 300 kg 661 39lb DC output interface The interface may be different depend on the connector CCS1 CCS2 CHAdeMO Cooling Liquid Liquid cooling Natural Forced air Ingression Protection NEMA3R Anti vandalism IK10 Excluding screen and RFID module 5 semaconnect com ...

Page 9: ...e shows the available combinations the coresponding posi tion of charging connectors are indicated from left to right when face to charger Version CHAdeMO CCS2 Liquid CCS2 Natural CCS1 Liquid CCS1 Natural 200A CCS1 Natural 300A DDWx362 V0U X X DDWx362 V0T X X U Natural cooling CCS1 combo V Liquid cooling CCS1 combo E Natural cooling CCS2 combo F Liquid cooling CCS2 combo For example G GB T DC T Re...

Page 10: ...rate dispenser or the rest two connectors finish the charging session 3 The connectors will get 90KW 25 and 270KW 75 output power when only two connectors are plugged in simultaneously in same dispenser or the rest two connectors finish the charging session 4 The connectors will get 90KW 25 90KW 25 and 180KW 50 output power when three connectors are plugged in simultaneously or the fourth connector ...

Page 11: ...ity tional safety standard and codes The max allowable distance between the power cabinet and the dispenser is 30m The power cabinet and the distribution box are recommended to keep distance from the end users to have better operation experience The similar design concept in appearance is recommended to the power cabinet and the distribution box Must use the CAT6 SFTP cable 24AWG or 26AWG with CAT...

Page 12: ...2 5 Dimensions Unit mm inch 2 6 Direction of Cooling Airflow Air In Air Out 700 27 56 550 21 65 1800 70 87 1860 73 23 900 35 43 9 semaconnect com ...

Page 13: ...njury or death WARNING Rotating parts Identifies a hazard that could result in injury due to the presence of rotating or moving parts WARNING Pinch Hazard Identifies a hazard that could result in injuries in which some body parts are pinched or crushed CAUTION Various Identifies a hazard that could result in damage to the machine other equipment and or environmental pollution NOTICE Contains remarks...

Page 14: ...ent wiring sys tem Connections shall comply with all applicable electrical codes Recommend ground resistance is less than 4 ohm 3 2 Grounding and Safety Requirements The dispenser aux power can be connected to 1 phase among L1 L2 or L3 to Neutral The capacity of power supply should be higher than 2 5kVA in order to have function correctly The product should be installed in well ventilated area and...

Page 15: ...nnected to neutral at only one point usually at the breaker panel 480V Three Phase Wiring Connection WARNING Earth Connection is Essential PE 277 Vac 277 Vac 277 Vac 480V Neutral L3 L1 L2 DANGERS Be Aware of High Voltage CAUTION The disconnect switch for each ungrounded conductor of AC input shall be provided by installation contractor or technician CAUTION A cord extension set or second cable ass...

Page 16: ... its final location last mile service is not standard included in the order NOTICE The delivery truck unloads the pallet carrying the DC 360KW Power Cabinet The movement of the DC 360kW Power cabinet to its final location is the responsibility of the customer contractor Checking the TiltWatch PLUS sensors If the TiltWatch PLUS indicator is tilted over 30 1 Do not refuse the delivery receipt 2 Make a...

Page 17: ...Please disassemble the shipping crate as follows STEP 1 STEP 2 Please remove the cardboard box and the protective internal packaging as follows 14 semaconnect com ...

Page 18: ...EP 3 To use lifting eye bolts to move the EVSE please apply 6mm 1 4 inches di ameter steel wire rope to the four eye bolts as following picture Make sure to tighten the eye bolts before lifting STEP 4 600m m 24 15 semaconnect com ...

Page 19: ...n the EVSE may vary depending on the designated application Each connector is recommended to use below cable Liquid 500A CCS1 CCS2 Conductor cross section Option 1 Conductor cross section 400 mm 800MCM at least Cable x 2 DC x1 DC x1 Option 2 Conductor cross section 125 mm 250MCM at least Cable x 4 DC x2 DC x2 Natural Cooling 300A CCS1 CCS2 Conductor cross section 150 mm 300MCM at least Cable x 2 D...

Page 20: ...Forklift Wire Stripper Wire cutters Residual Current Device 30mA type A 2 pole No Fuse Breaker Curve B for capacitive load Please follow all local safety standards and electrical codes at all times even if the actual installation process and procedures are varied to accommodate the existing site condition 3 4 2 Recommended Tools for Inspection Commissioning Type Description EV or EV Simulator Meet...

Page 21: ...d onto the base The positioning of these 4 pcs of M12 screws should be within 2mm in short axis 14mm in long axis according to screw holes of charger Add drain pipe at opening of concrete base to prevent stand ing water Recommend to use a prefabricated steel mould for constructing the cement concrete base per dimensions provided below 3 5 1 Build Concrete Base Unit mm 200 30 600 ConcreteBase GROUN...

Page 22: ...ase AC ca ble expose at least 270mm 10 63 and be with ring terminals The conduc tor cross sectional area of input power wires should be not less than 2 5mm AWG12 Extend 2 sets DC power cable from conduit of concrete base Gun1 DC cable expose at least 840mm 33 07 DC cable expose at least 910mm 35 83 Gun2 DC cable expose at least 840mm 33 07 DC cable expose at least 620mm 24 41 and be with ring term...

Page 23: ...r bolt from the cement base 2 nuts for each bolt to secure the chargers Method 1 3 5 2 Two Methods of Fixing the Charger 100cm 39 37 keep at least 100cm 39 37 clearance distance for the cabinet Front AC cables length 270mm 10 63 DC cables length 840mm 33 07 DC cables length 910mm 35 83 DC cables length 840mm 33 07 PE cables length 620mm 24 41 DC cables length 910mm 35 83 Must use CAT6A FTP RJ45 Pl...

Page 24: ...rackets on the cabinet base with the M12xL130 expansion screws Material Stainless steel drill 4x Φ12mm screw holes on the concrete base secure L shaped brackets on the concrete base by 4 pcs M12 expansion bolts Method 2 NOTE If remove the eye bolts on the top of the cabinet must assemble the water proof plastic bolts Inside in the accessory pack 21 semaconnect com ...

Page 25: ...ower cabinet to paired busbar STEP 1 L Brown Neutral Blue PE Green with Yellow PE L N Communication Cable Connector DC Connector DC Connector DC Connector DC Left door Right door Left Door Right Door The charging connectors installed on the EVSE may vary depending on the designated application The charging connectors installed on the EVSE may vary depending on the designated application 22 semacon...

Page 26: ...ed with ground point to meet TN S grounding system STEP 3 Use adaptive flame retardants and electrical insulated foaming agent and far from conductive live part at least 12mm AWG 6 or other method to seal the cable entry hole to assure the NEMA3R grade of the cabinet and prevent in sects enter the cabinet STEP 4 A 20A NFB for capacitve load and 30mA RCD type A is recommended to use on power distri...

Page 27: ...Car bumper or bollard Anti vandalism measures 3 6 2 External Infrastructure Readiness Check Item Status Remark Cement stand Base Input Wirings Terminals Type Length cross section Key Lock of Cabinet Door Type No Fixing Screws 30mA type A 2 pole No Fuse Breaker 20A for capacitive load Grounding Resistance 4Ω Network Connection Quality Wi Fi 3G 4G 65dBm 3 6 3 EVSE Check Prior to installation energiz...

Page 28: ...tion RFID User Authorization QR Code User Authorization Others Waiting Time of Connection Check Reading of Each Display Item Full Charge Test Function of Electronic Lock Airflow Cooling Fan cooling unit of charging gun 2 RJ45 connector Robustness of Output Wirings DC power cables Coolant Level No leakage Dispense Cabinet ID 1 for single or left cabinet 2 for right cabinet Item Status Remark Emerge...

Page 29: ... 30 98 190 253 18 63 24 8 M10 1 5 Hex cap 212 382 245 440 24 02 43 15 196 351 19 22 34 42 M12 1 75 Hex cap 372 668 430 770 42 17 75 49 343 615 33 63 60 3 Screw in Imperial 2 56 Machine 1 5 2 1 7 2 3 0 17 0 22 1 4 1 8 0 14 0 18 4 40 Machine 3 4 3 5 4 5 0 34 0 44 2 8 3 6 0 27 0 35 6 32 Machine 6 10 7 11 5 0 68 1 13 5 6 9 2 0 55 0 9 8 32 Machine 10 15 11 5 17 1 13 1 66 9 2 14 0 9 1 37 10 32 Machine 1...

Page 30: ...s 4 1 Operating Sequence When the charger is powered on it start with the Charging Station Initializing page You will see the below image on the screen after powering on and the system is initializing The initializing process will take around 2 minutes then shows home page 4 2 Operating Procedure 4 2 1 System Initialization Initializing page 27 semaconnect com ...

Page 31: ... Status Wi Fi Status Unit and currency if billing function is enabled Ethernet Backend Status Home page Connection Dis Connection Connection Dis Connection Connection Dis Connection OCPP Backend Status Connection Dis Connection User authorization Method RFID QR code and mobile APP Unauthorized method s will be darker on the screen if the method is disable Home page 28 semaconnect com ...

Page 32: ... The charger will automatically detect the type of the charging connector It will normally take less than 10 seconds to start the process after completing the physical connection of charging connector to charging inlet To terminate this session please press the left button to return to the Home page Press left button to terminate this charging session and then return to Home page Plug in page User...

Page 33: ...n of Selected Charging Connector Connector Select Button Preparing page Press right button to select the char ger connector that the user would like to use Charging page The screen will show the Charging Page as below illustrated once the charger goes into the ready to charge stage Charging information area EV battery SOC Show the selected connector in use Charging duration Charged power Energy 30...

Page 34: ...ector that the user would like to stop User also can tap the RFID to stop charging To start charging load the charging information When the battery has been fully charged or reaches the limit of the setting it will stop charging automatically and go to the next process 31 semaconnect com ...

Page 35: ...ector to charging cable holder The screen will go back to the Home Page or the other charging connec tor s Charging Page if unplugged from the charging connector During simultaneous charging the screen will go to the other charging connector s Charging Page if either charging connector is unplugged 4 2 6 Charging Terminated 4 2 7 Status Messages Charging energy Charging duration Charging power Cha...

Page 36: ...C input contactor 1 welding 011006 AC input contactor 1 driving fault 011007 AC input contactor 2 welding 011008 AC input contactor 2 driving fault 011009 AC output relay welding 011010 AC output relay driving fault 011011 CHAdeMO output relay welding 011012 CHAdeMO output relay driving fault 011013 CCS output relay welding 011014 CCS output relay driving fault 011015 GB output relay welding 01101...

Page 37: ...tter fault 011035 Ble module broken 011036 Rotary switch fault 011037 CCS liquid chiller water level fault 011038 Reserved 011039 Reserved 011040 Reserved 012200 System L1 input OVP 012201 System L2 input OVP 012202 System L3 input OVP 012203 System L1 input UVP 012204 System L2 input UVP 012205 System L3 input UVP 012206 PSU L1 input OVP 012207 PSU L2 input OVP 012208 PSU L3 input OVP 012209 PSU ...

Page 38: ... 012227 Aux power module OTP 012228 Relay board smart box OTP 012229 CHAdeMO connector OTP 012230 CCS connector OTP 012231 GB connector OTP 012232 AC connector OTP 012233 RCD CCID trip 012234 CHAdeMO GFD trip 012235 CCS GFD trip 012236 GB GFD trip 012237 SPD trip 012238 Main power breaker trip 012239 Aux power breaker trip 012240 PSU communication fail 012241 WiFi module communication fail 012242 ...

Page 39: ...deMO groundfault detection timeout GFD 012260 CCS groundfault detection timeout GFD 012261 GB groundfault detection timeout GFD 012262 System AC L1 output Circuit Short 012263 PSU Duplicate ID 012264 PSU Output Short Circuit 012265 PSU Discharge Abnormal 012266 PSU Dc Side ShutDown 012267 PSU Failure Alarm 012268 PSU Protection Alarm 012269 PSU FanFailure Alarm 012270 PSU Input UVP 012271 PSU Inpu...

Page 40: ...VP 012291 Self test Failed due to communication of GBTboard failure 012292 Self test Failed due to communication of AC failure 012293 Self test Failed due to communication of Ledboard failure 012294 AC input ovp 012295 AC input uvp 012296 CHAdeMO groundfault detection warning 012297 CCS groundfault detection warning 012298 GB groundfault detection warning 012299 System AC L2 output OCP 012300 Syst...

Page 41: ...tput line 012325 Connector 2 detects abnormal voltage on the output line 012326 System task is lost 012327 Reserved 012344 Meter IC communication timeout 012345 Pilot negative error 013600 Normal stop charging by user 013601 Charging Time s up 013602 Replace system air filter 013603 Reach to CHAdeMO max plugging times 013604 Reach to CCS max plugging times 013605 Reach to GB max plugging times 0136...

Page 42: ...from Internet through 3G 4G 013625 disconnected from AP through WiFi 013626 disconnected from APN through 3G 4G 013627 WiFi disabled separated charger only 013628 4G disabled separated charger only 013629 Reserved 013630 Reserved 013631 Reserved 023700 CHAdeMO EV communication Fail 023701 CCS EV communication Fail 023702 GB EV communication Fail 023703 AC pilot fault 023704 CHAdeMO battery malfunc...

Page 43: ... before stop 023729 CHAdeMO charger get normal stop cmd 023730 CHAdeMO charger get emergency stop cmd 023731 CHAdeMO isolation result fail 023732 CHAdeMO mother board miss link 023733 CHAdeMO output voltage more than limit 023734 CHAdeMO req current more than limit 023735 CHAdeMO re capability bms eqr current exceed 023736 CHAdeMO charge remaining count done 023737 CCS_EVCC_EVErrorCode_FAILED_RESS...

Page 44: ...CC_ResponseCode_FAILED_SignatureError 023760 CCS_SECC_ResponseCode_FAILED_UnknownSession 023761 CCS_SECC_ResponseCode_FAILED_ServiceIDInvalid 023762 CCS_SECC_ResponseCode_FAILED_Payment SelectionInvalid 023763 CCS_SECC_ResponseCode_FAILED_IdentificationSelectionInvalid 023764 CCS_SECC_ResponseCode_FAILED_ServiceSelectionInvalid 023765 CCS_SECC_ResponseCode_FAILED_CertificateExpired 023766 CCS_SECC_R...

Page 45: ...LED_AssociationError 023788 CCS_SECC_ResponseCode_FAILED_EVSEChargeAbort 023789 CCS_SECC_ResponseCode_FAILED_NoSupportedApp Protocol 023790 CCS_SECC_ResponseCode_FAILED_ContractNotAccepted 023791 CCS_SECC_ResponseCode_FAILED_MOUnknown 023792 CCS_SECC_ResponseCode_FAILED_OEM_Prov_CertificateRevoke 023793 CCS_SECC_ResponseCode_FAILED_OEM_SubCA1_ CertificateRevoked 023794 CCS_SECC_ResponseCode_FAILED_O...

Page 46: ..._TIMEOUT_SLAC_TP_EVSE_avg_atten_calc 023814 CCS_SECC_TIMEOUT_SLAC_CM_ATTEN_CHAR_RSP 023815 CCS_SECC_TIMEOUT_SLAC_CM_VALIDATE_REQ_1ST__CM_SLAC_ MATCH_REQ 023816 CCS_SECC_TIMEOUT_SLAC_TT_EVSE_assoc_session 023817 CCS_SECC_TIMEOUT_SLAC_TT_EVSE_vald_toggle 023818 CCS_SECC_TIMEOUT_SLAC_CM_MNBC_SOUND_IND 023819 CCS_SECC_TIMEOUT_SLAC_CM_VALIDATE_REQ_2ND__CM_SLAC_ MATCH_REQ 023820 CCS_SECC_TIMEOUT_SLAC_re...

Page 47: ...OUT_V2G_Msg_Performance_Time_ PowerDeliveryRes 023839 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_ CableCheckRes 023840 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_PreChargeRes 023841 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_ CurrentDemandRes 023842 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_ WeldingDetectionRes 023843 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_ SessionStopRes 023844 CCS_SECC_TIMEOUT_V...

Page 48: ...65 CCS_CAN_TIMEOUT_TP_DOWNLOAD_REQUEST 023866 CCS_CAN_TIMEOUT_TT_DOWNLOAD_REQUEST 023867 CCS_CAN_TIMEOUT_TP_START_BLOCK_TRANSFER 023868 CCS_CAN_TIMEOUT_TT_START_BLOCK_TRANSFER 023869 CCS_CAN_TIMEOUT_TP_DATA_TRANSFER 023870 CCS_CAN_TIMEOUT_TT_DATA_TRANSFER 023871 CCS_CAN_TIMEOUT_TP_DOWNLOAD_FINISH 023872 CCS_CAN_TIMEOUT_TT_DOWNLOAD_FINISH 023873 CCS_CAN_TIMEOUT_TP_ISOLATION_STATUS 023874 CCS_CAN_TI...

Page 49: ...893 CCS_SECC_FAIL_QCA7000_SETKEY 023894 Reserved 023895 Reserved 023896 Reserved 023897 Reserved 023898 Reserved 023899 Reserved 023900 GBT_LOS_CC1 023901 GBT_CONNECTOR_LOCK_FAIL 023902 GBT_BATTERY_INCOMPATIBLE 023903 GBT_BMS_BROAA_TIMEOUT 023904 GBT_CSU_PRECHARGE_TIMEOUT 023905 GBT_BMS_PRESENT_VOLTAGE_FAULT 023906 GBT_BMS_VOLTAGE_OVER_RANGE 023907 GBT_BSM_CHARGE_ALLOW_00_10MIN_COUUNTDONE 023908 G...

Page 50: ... Reserved 023927 Reserved 023928 Reserved 023929 Reserved 023930 GBT_CEM_BHM_TIMEOUT 023931 GBT_CEM_BRM_TIMEOUT 023932 GBT_CEM_BCP_TIMEOUT 023933 GBT_CEM_BRO_TIMEOUT 023934 GBT_CEM_BCL_TIMEOUT 023935 GBT_CEM_BCS_TIMEOUT 023936 GBT_CEM_BSM_TIMEOUT 023937 GBT_CEM_BST_TIMEOUT 023938 GBT_CEM_BSD_TIMEOUT 023939 GBT_CEM_BEM_OTHER_TIMEOUT 023940 GBT_BEM_CRM_TIMEOUT 023941 GBT_BEM_CRMAA_TIMEOUT 023942 GBT...

Page 51: ...GE_CONNECTOR 023958 GBT_BST_OTP 023959 GBT_BST_OTHER 023960 GBT_BST_HIGH_V 023961 GBT_BST_CC2 023962 GBT_BST_CURRENT 023963 GBT_BST_VOLTAGE 023964 GBT_GET_BST_NO_REASON 023965 Reserved 023966 Reserved 023967 Reserved 023968 Reserved 023969 Reserved 023970 GBT_BSM_CELL_OVER_VOLTAGE 023971 GBT_BSM_CELL_UNDER_VOLTAGE 023972 GBT_BSM_OVER_SOC 023973 GBT_BSM_UNDER_SOC 023974 GBT_BSM_CURRENT 023975 GBT_B...

Page 52: ...eset by backend 033906 Reserved 033907 Reserved 041004 RCD CCID self test fail 041005 AC input contactor 1 welding 041006 AC input contactor 1 driving fault 041007 AC input contactor 2 welding 041008 AC input contactor 2 driving fault 041009 AC output relay welding 041010 AC output relay driving fault 041017 AC connector temperature sensor broken 041021 WiFi module broken 041022 3G 4G module broke...

Page 53: ...nput drop 042214 System L3 input drop 042223 System ambient inlet OTP 042224 System critical point OTP 042225 PSU ambient inlet OTP 042226 PSU critical point OTP 042227 Aux power module OTP 042228 Relay board smart box OTP 042232 AC connector OTP 042233 RCD CCID trip 042237 SPD trip 042238 Main power breaker trip 042239 Aux power breaker trip 042240 PSU communication fail 042241 WiFi module commun...

Page 54: ...nput UVP 042271 PSU Input OVP 042272 PSU WalkIn State 042273 PSU Power Limited State 042274 PSU Id Repeat 042275 PSU Severe Uneven Current 042276 PSU Three Phase Input Inadequate 042277 PSU Three Phase Onput Imbalance 042278 PSU Ffc Side ShutDown 042279 NO PSU Resource 042280 Self test Failed due to communication of Relayboard failure 042281 Self test Failed due to communication of Fanboard failur...

Page 55: ...ted from dispenser 042305 Meter communication timeout 042306 The dip switch of the PSU may be incorrect 042307 Psu Fuse Burn Out 042308 Psu Pfc And Dcdc Communication Fault 042309 Psu Bus Voltage Unbalance 042310 Psu Bus Over Voltage 042311 Psu Bus Voltage Abnormal 042312 Psu Bus Under Voltage 042313 Psu Input Phase Loss 042314 Psu Fan Full Speed 042315 Psu Temperature Power Limit 042316 Psu Ac Po...

Page 56: ...619 configured by USB flash drive 043620 configured by backend 043621 configured by webage 043622 disconnected from Internet through Ethernet 043623 disconnected from Internet through WiFi 043624 disconnected from Internet through 3G 4G 043625 disconnected from AP through WiFi 043626 disconnected from APN through 3G 4G 043627 WiFi disabled separated charger only 043628 4G disabled separated charger o...

Page 57: ...ts If there is water intruding into the DC Fast Charger then please cut off the power source immediately and contact the DC Fast Charger provider for repair Please loop the cable nicely around the bundle and wrap it gently back onto the holder Please attach the charging connector back to the holster securely If there is damage to the charging connector charging cable or holder of the charging conn...

Page 58: ...ooling unit and coolant every 3 months Do not twist swing bend drop or crush the charging cable Never drive over it with a vehicle Make sure that the minimum bending radius is not exceeded After charging place the cable immediately back into the holder of the charging station Leakage or material degradation may occur if a coolant other than that specified by the manufacturer of the accessory is use...

Page 59: ...l for liquid cooled charging cable system A Recommended maintenance interval every 3 months or as needed Connector Visual inspection for defects or damage Check cover for scratches When exchanging the cover check for mechanical damages Check the screws for secure fastening Clean the outside of the connector with damp cloth Clean the outside of the connector with a wet cotton towel Max 150mm 5 91 M...

Page 60: ...nction Cooling Unit Visual inspection for defects or damage Check the cooling unit for secure fastening Check the level of the coolant Cable Visual inspection for defects or damage Check the charging cable for secure fastening Clean the charging cable with a wet cotton towel Cooling Unit Visual inspection for defects or damage Check the cooling unit for secure fastening 57 semaconnect com ...

Page 61: ...C charging connector 4M or above charging cable depending on the connector that shipped Charging Cable Holder Emergency Stop Button MW Aux Power HEP 100 12V 24V for DWIN Panel Backplane Control Supervisory Unit CSU3 1 Surge Protection Device SPD DC Fan Air Filters Door Key Gland M50 User Manual Relay Coolant Cooling unit Relay board Fan board LED board Hub 58 semaconnect com ...

Page 62: ...ghting earthquake fire flood pest damage abuse accident misuse negligence or failure to maintain the product or other event beyond Supplier s reasonable control or not arising from normal operating condition 2 Cosmetic or superficial defect dents marks or scratches after use 3 d n a t n e m p i u q e y r a l l i c n a t c u d o r p e h t m o r f e t a r a p e s e r a h c i h w s t n e n o p m o C co...

Page 63: ...g the warranty period and provide the model number series number proof of pur chase and date of purchase This warranty does not cover the damages result in resulting from adapter acci dent or damages resulting from unauthorized service 60 Appendix Package list Item Description No Remark 1 EVSE Power Dispenser 1 2 User Manual 1 3 OQC Report 1 4 RFID Card 2 5 Key of cabinet 1 6 MSDS Coolant CP3 002 ...