8.
Maintenance
20
117127
● 07/2011
8.4 Cleaning
Clean lift regularly.
Clean lift only in unloaded condition.
Do not use aggressive cleaning agents for lift
components and covers.
Only use lint-free cleaning cloths.
Do not use compressed air or high-pressure
cleaners.
Always call in the appointed maintenance repre-
sentative if hazards are detected.
At the start of cleaning, make sure you clean
connections and screw joints of oil, lubricants
and cleaning agents.
8.5 Check hydraulic oil level
Check oil levels on all lifting cylinders.
1. Lower all lifting cylinders completely.
2. Remove dipsticks and check hydraulic oil level.
3. Refill hydraulic oil (
chapter 8.6) up to filling
level, if necessary.
4. Replace dipstick.
5. Calibrate the sensor setting after every interven-
tion in the hydraulic system (
chapter 8.13).
8.6 Permitted hydraulic oils
Important notes
Only use hydraulic oil according to DIN 51524 for
the hydraulic system.
Contact us when using hydraulic oil of other
manufacturers.
Oil and lubricants are hazardous to water. Always
dispose of these substances in an environmental-
ly friendly manner according to the regulations in
your country (
chapter 15, Disposal).
ATTENTION
Damage to seals with use of incor-
rect hydraulic oil.
Do not use oil based on rapeseed oil.
The water content in the oil is not to exceed
2%.
Do not mix different types of oil.
Manufacturer
Oil type
ARAL
Vitamin
BP
Energol HLP 22, HLP-D 22
ESSO
ESSTIC 22, Nuto H22
FINA
Hydran 22, Circan 22
FUCHS
Renolin MR, Renolin B
MOBIL OIL
Mobil D.T.E
SHELL
Hydrol DO 22
TEXACO
Rando Oil 22, -HDC-22
VALVOLINE
ETC
VEDOL
Andarin 22