Operating instructions 

 
 

CONNECTION TO THE 
COMPRESSED AIR MAINS 

 

Warning

- Pressure in the mains 

The compressed air mains might be under pressure, 
and working on mains that are under pressure can 
result in injury. Therefore, first shut the mains off 
from all sources of pressure and let the air out. 
 

 

Compressed air connection with flexible 

hosepipes 

Use a suitable flexible hosepipe for connection to the 
compressor. This will prevent tension from causing 
cracks, and also noise from being transmitted. 
Connecting pipes and couplings of the right size and 
grade for the relevant operating pressures and 
temperatures must always be used, and components 
that are in a faultless condition. 
 

CONNECTION TO THE ELECTRIC 
MAINS 

 

Warning

- drive belt guard 

Wheels, drive belts, and fan blades can cause very 
severe injuries when the are in motion. The compres-
sor must never be given a trial run or started up 
unless the drive belt guard is in place and the housing 
closed. 

Exception: Machines with a sound-insulation 
hood 

can be run with side cover open to check the 

direction of rotation, but this must be done very 
carefully.

 

 

INSTRUCTIONS FOR MACHINES WITH 
SOUND-INSULATION HOOD 

Machines which are fitted with a sound-insulation 
hood are also fitted with ventilation fan to prevent a 
build-up of heat. After the machine has been swit-
ched off, this fan continues to run for a short time 
until the machine has cooled down. 
 

INSTRUCTIONS FOR ELECTRICAL 
CONNECTION 

• 

The electrical connection and safety precautions 
must comply with VDE regulations and/or other 
regulations in force in the country of operation, 
including those issued by the local power supply 
utility. 

• 

Always check the direction of rotation before 
starting the compressor up. 

• 

Units connected without a  plug connection 
should be fitted with a lockable main switch as 
well as a suitable main fuse. 

• 

Please refer to the technical data for the necessary 
cross-sectional size of the wiring and the rating of 
the fuse. 

 

CHECKING THE DIRECTION OF ROTATION 

⇒ 

Switch the machine on or plug it in. 

⇒ 

Turn the master switch on and immediately off 
again. 

⇒ 

If the ventilator wheel turns in the direction of the 
arrow, this is correct; if not, reverse the poles on 
the motor. 

 

 
STARTING UP AND OPERATING 

STARTER SWITCH 

 

Warning

- hot surfaces

 

The compressor block and the air leads coming from 
it can become very hot during operation. Avoid the 
risk of burns, and do not touch the hot parts of the 
compressor. 
 

 

Warning

!

 - drive belt guard 

Wheels, drive belts, and fan blades can cause very 
severe injuries when the are in motion. The compres-
sor must never be started up unless the drive belt 
guard is in place and the housing closed. 
 

SWITCHING THE MACHINE ON 

⇒ 

Check the starter switch - it must be set at the “0” 
position. 

⇒ 

Check the oil level (GKTE, GKTZ, GKTZH) 

⇒ 

Switch the master switch on or plug in. 

⇒ 

Set the starter switch to the “1” position, and the 
machine is now ready to operated. 

• 

The compressor starts automatically when 
compressed air is drawn off and the pressure in 
the storage tanks falls below a pre-set level. It is 
therefore possible that the compressor does not 
start up as soon as it is switched on, and that it 
only switches off after a certain time delay (see 
pressure switch). 

• 

The compressor stops automatically as soon as 
full pressure is attained. 

Summary of Contents for DZNT series

Page 1: ...IL FREE PISTON COMPRESSORS TYPE DZNT GZNT GZNTS GKTE GKTZ GKTZH IDENT NR 50140 980 25 03 2003 BLITZ M SCHNEIDER WERKZEUG UND MASCHINENFABRIK GMBH H FINGER STRASSE 55 D 78199 BR UNLINGEN PHONE 07 71 92...

Page 2: ...ructions 2 1 control flange 7 belt guard 2 manometer 8 motor 3 safety valve 9 compressor block 4 pressure switch 10 air receiver 5 condensate drain 11 electric control unit 6 air outlet 12 cooler with...

Page 3: ...takes inadequate maintenance incorrect consumable material installation of the wrong replacement parts please only ever use original Blitz parts improper technical alterations to the machine failure t...

Page 4: ...sh to the ground and could cause very serious injury It is strictly forbid den to move or stand in the danger area underneath a suspended load CAUTION Improper lifting Lifting the compressor in the wr...

Page 5: ...r other regulations in force in the country of operation including those issued by the local power supply utility Always check the direction of rotation before starting the compressor up Units connect...

Page 6: ...hem The master switch must be switched off or the plug pulled out of the mains socket before any maintenance work is done Warning air pressure in the machine Even if the machine is switched off the ai...

Page 7: ...this work OIL CHANGE INTERVALS Mineral oil every 500 operating hours Synthetic oil every 1 000 operating hours Carry out an oil change at least once a year PROCEDURE Oil quantity see technical data L...

Page 8: ...lt for compressor drive is tensioned by displacing of electric motor Loosen the fixing screw of the motor by few turns Displace the motor until the v belt is tensioned Retension the fixing screw The v...

Page 9: ...t Air is escaping through the safety valve on the storage tank Pressure switch is set too high Check the pressure switch settings Air is escaping from the depres surisation pipe on the pressure switch...

Reviews: