background image

Operating instructions 

 
 

6

 

 

SWITCHING THE MACHINE OFF 

CAUTION!

 

Mistakes when switching off 

Avoid causing damage to the electric motor, and only 
ever switch the machine off at the starter switch. Do 
not use the lockable master switch for this purpose, 
and never pull the main plug out when the machine is 
switched off. 

⇒ 

Set the starter switch to the “0” position. 

• 

The motor and the compressor will now switch 
off. 

• 

The compressed air line between the compressor 
and the storage tank will let the air off automati-
cally, so as to ensure that the compressor can start 
up again with no load against it. 

• 

Pressure in the storage tank will be maintained. 

⇒ 

Turn the lockable master switch off or plug off. 

 

PROTECTING THE MOTOR FROM 
EXCESSIVE TEMPERATURE 

 

Warning!

 unexpected start 

Units with automatic pressure switch can start by 
themselves once the unit has cooled down. This 
means people are at risk. For this reason once the 
motor protection has been triggered off the unit 
should be turned off at the operating switch. 
If an excessive load on the machine or too high an 
ambient temperature causes an excessively high 
temperature in the electric motor, the motor cut-out 
on the compressor will automatically shut the 
machine down. 
 

THE FOLLOWING STEPS MUST BE TAKEN 
WHEN THE CUT-OUT HAS BEEN 
TRIGGERED OFF: 

⇒ 

Switch the machine off at the starter switch. 

⇒ 

Discover and rectify the cause of the malfunction. 

⇒ 

Wait another 15 to 20 minutes for the motor to 
cool down. 

⇒ 

Reverse the motor protection switch on units with 
manual motor protection. 

⇒ 

Restart the machine. 

 
MAINTENANCE 

 

Warning

- electrical tension 

Even if the machine is switched off, there will still be 
current in some of the circuits, and electric shocks 
can cause injury if work is being done on them. The 
master switch must be switched off or the plug pulled 
out of the mains socket before any maintenance work 
is done. 
 

 

Warning

!

 - air pressure in the machine 

Even if the machine is switched off, the air in the 
pipes can still be under pressure, and the unexpected 
escape of compressed air can cause injury if work is 
being done on them. Pressure must always be let off 
from the machine before any maintenance work is 
done. 
 

LETTING AIR OFF FROM THE MACHINE 

• 

The compressor block releases its air pressure 
automatically if the plant is switched off in the 
proper way (see “Starting up and operating”). 

• 

To deaerate the air receiver open the condensate 
drain and let the total pressure off. 

 

TO DRAIN THE AIR RECEIVER OF 
CONDENSATE  

On units with air receiver open the condesate drain 
„under pressure“ until pure compressed air issues. 
Then close the drain again.  Condensate contains oil 
and must therefore be disposed of in an environmen-
tally responsible way. 
 

CHECK THE OIL LEVEL (only for 
units of type GKTE, GKTZ, GKTZH) 

CAUTION!

 

Condensation can ruin the machine 

completely 

If the machine is set up in a cool, damp place, such as 
in a cellar, condensation can form in the lubricating 
oil. This is particularly likely to happen if the 
compressor is run for too short a time and thus does 
not reach its full operating temperature. This conden-
sation then reduces the lubricating effect on pistons 
and bearings, and that could destroy them com-
pletely. The signs of condensation in the lubricating 
oil are an excessively high oil level, a milky colour in 
the oil, or drops of water in the inspection window. If 
any of these occur, the oil must be changed at once. 
Remedy: install the compressor in a warm, dry room, 
or use a smaller compressor. 
 

• 

Check the oil level weekly, and top up with an 
appropriate oil if necessary. 

• 

Never mix oil of different types or quality grades 
together. 

• 

The oil level in the inspection window must lie 
within the marked circle. 

Summary of Contents for DZNT series

Page 1: ...IL FREE PISTON COMPRESSORS TYPE DZNT GZNT GZNTS GKTE GKTZ GKTZH IDENT NR 50140 980 25 03 2003 BLITZ M SCHNEIDER WERKZEUG UND MASCHINENFABRIK GMBH H FINGER STRASSE 55 D 78199 BR UNLINGEN PHONE 07 71 92...

Page 2: ...ructions 2 1 control flange 7 belt guard 2 manometer 8 motor 3 safety valve 9 compressor block 4 pressure switch 10 air receiver 5 condensate drain 11 electric control unit 6 air outlet 12 cooler with...

Page 3: ...takes inadequate maintenance incorrect consumable material installation of the wrong replacement parts please only ever use original Blitz parts improper technical alterations to the machine failure t...

Page 4: ...sh to the ground and could cause very serious injury It is strictly forbid den to move or stand in the danger area underneath a suspended load CAUTION Improper lifting Lifting the compressor in the wr...

Page 5: ...r other regulations in force in the country of operation including those issued by the local power supply utility Always check the direction of rotation before starting the compressor up Units connect...

Page 6: ...hem The master switch must be switched off or the plug pulled out of the mains socket before any maintenance work is done Warning air pressure in the machine Even if the machine is switched off the ai...

Page 7: ...this work OIL CHANGE INTERVALS Mineral oil every 500 operating hours Synthetic oil every 1 000 operating hours Carry out an oil change at least once a year PROCEDURE Oil quantity see technical data L...

Page 8: ...lt for compressor drive is tensioned by displacing of electric motor Loosen the fixing screw of the motor by few turns Displace the motor until the v belt is tensioned Retension the fixing screw The v...

Page 9: ...t Air is escaping through the safety valve on the storage tank Pressure switch is set too high Check the pressure switch settings Air is escaping from the depres surisation pipe on the pressure switch...