Instruction Manual for Mobile Jacks
11
Electrical Connection
E
WARNING
Risk of injury and material damage from electric shock
The electrical connection and the applicable national protection regulations shall be provided
and checked by a specialist.
The electrical connection must be composed of a cable with 5-pin CEE coupling 16 A, which is
connected to a 400 V/50 Hz mains supply. A circuit breaker of 3.8 A must exist.
The manufacturer recommends a suitable cable suspension system.
4
Commissioning
Before initial operation:
Connect the compressed air supply or the electrical connection to the lift.
Check the hydraulic fluid level. (
Perform a safety check (
5
Operation
5.1
Load-carrying Devices
Safety Notes
Do not stack extensions.
Always use original load-carrying devices of the manufacturer with suitable pins.
Support plate and extension
Traverse
Lift a vehicle at one point.
Lift vehicles gently at two points.