11. IMPIANTO ELETTRICO
Installazione
da
eseguire
dallutilizzatore
11. ELEKTROANLAGE
Netzanschluss
durch
Elektrofachkräfte
11. INSTALACIÓN ELECTRICA
Instalación
que
debe
efectuar
el
utilizador
11
11. WIRING DIAGRAM
Power
installations
must
be
made
by
the
user.
11. INSTALLATION ELECTRIQUE
Installation
à
effectuer
par
lutilisateur
11.1 IMPIANTO ELETTRICO QUADRO PRINCIPALE
11.1 WIRING DIAGRAM MAIN BOARD
11.1 ELEKTRISCHEN ANLAGE - HAUPTSCHALTTAFEL
11.1 INSTALLATION ELECTRIQUE - TABLEAU PRINCIPAL
11.1 INSTALACIÓN ELECTRICA CUADRO PRINCIPAL
REF.DENOMINATIONS
TERMINAL
TR
TRANSFORMER
160VA
VP
0/230/400
VS
0/24
-
0/18
STM
MOTOR
HEAT
PROBE
SCA
ALIGNEMENT
CONTROL
BOARD
RC
CONTACTOR
COIL
ANTI-NOISE
K1
EMERGENCY
RELAY
KSF
PHASE
SEQUENCE
CONTROL
RELAY
KS
RISE
CONTROL
CONTACTOR
KM
MOTOR
CONTROL
CONTACTOR
KD
DESCENT
CONTROL
CONTACTOR
PS
UP
BUTTON
PD
DOWN
BUTTON
M
MOTOR
LS2
BLOCK
AND
EMERGENCY
RED
WARNING
LIGHT
LS1
CORRECT
PHASE
SEQUENCE
WHITE
WARNING
LIGHT
IG
MAIN
SWITCH
(32A)
FU4
SECONDARY
PROTECTION
FUSE
(18V)
TR
5x20F
2A
250V
QUICK
FU3
SECONDARY
PROTECTION
FUSE
(24V)
TR
5x20F
5A
250V
QUICK
FU2
PRIMARY
PROTECTION
FUSES
TR
10x38
4A
500V
gl
(230v)
2a
500v
gl
(400V)
FU1
MOTOR
LINE
FUSES
10x38
16A
500V
aM
(230v)
8a
500v
am
(400V)
FU0LINE
FUSES
14x51
50a
400V
AM
(230V)
32A
500V
AM
(400V)
FCS
RISE
LIMIT
SWITCH
FCP
PROXIMITY
LIMIT
SWITCH
FCD
DESCENT
LIMIT
SWITCH
CNF2/3/4
FEMALE
CONNECTOR
TO
SATELLITE
POSTS
RIFER.
NOMENCLATURA
MORSETTO
TR
TRASFORMATORE
160VA
Vp
0/230/400
Vs
0/24
-
0/18
STM
TERMOSONDA
MOTORE
SCA
SCHEDA
CONTROLLO
ALLINEAMENTO
RC
ANTIDISTURBO
BOBINA
CONTATTORI
K1
RELE
EMERGENZA
KSF
RELE
CONTROLLO
SEQUENZA
FASI
KS
CONTATTORE
COMANDO
SALITA
KM
CONTATTORE
COMANDO
MOTORE
KD
CONTATTORE
COMANDO
DISCESA
PS
PULSANTE
DI
SALITA
PD
PULSANTE
DI
DISCESA
M
MOTORE
LS2
SPIA
ROSSA
EMERGENZA
E
BLOCCO
LS1
SPIA
BIANCA
SEQUENZA
FASI
CORRETTA
IG
INTERRUTTORE
GENERALE
(32A)
FU4
FUS.PROTEZIONE
SECONDARIO
(18V)
TR
5X20F
2A
250V
RAPIDO
FU3
FUS.PROTEZIONE
SECONDARIO
(24V)
TR
5X20F
5A
250V
RAPIDO
FU2
FUSIBILI
PROTEZ.PRIMARIO
TR
10X38
4A
500V
GL
(230V)
2A
500V
GL
(400V)
FU1
FUSIBILI
PROT.LINEA
MOTORE
10X38
16A
500V
AM
(230V)
8A
500V
AM
(400V)
FU0FUSIBILI
PROTEZ.
LINEA
14X51
50A
400V
AM
(230V)
32A
500V
AM
(400V)
FCS
FINECORSA
SALITA
FCP
INTERRUTTORE
DI
PROSSIMITA
FCD
FINECORSA
DISCESA
CNF2/3/4
CONNETTORE
FEMMINA
COLLEGAMENTO
COLONNE
SATELLITI
Summary of Contents for MRG25-4
Page 12: ...12 2 Kg 2500 1 1...
Page 22: ...22 1 2 3 1...
Page 24: ...24 1 2 3 9 4 5 6 8 4 6...
Page 28: ...28 6 Q R1 R1 Q 3000 kg R1 1400 kg S2 S3 S4 P1...
Page 42: ...42 7 E B D C A S2 S3 S4 P1 S2 S3 S4...
Page 44: ...44 7 1 2 E B D C A...
Page 46: ...46 7 S2 S3 S4 P1...
Page 48: ...48 7...
Page 50: ...50 7 2 1 E B D C A...
Page 56: ...56 9 1 2...
Page 58: ...58 9...