Page 11
SwitchBlade™ X3 Manual Rev. A
© 2014 Blizzard Lighting, LLC
Control Panel Menu Structure
Addr
d001 - d512
To choose the DMX address
cLnd
Select Pan/Tilt Direction
H Y
Normal Pan / Normal Tilt Direction
H - Y
Normal Pan / Reverse Tilt Direction
-H Y
Reverse Pan / Normal Tilt Direction
-H -Y
Reverse Pan / Reverse Tilt Direction
SLnd
HoST
Run the Fixture in Master
SLAV
Run the Fixture in Slave
dISP
oFF - on
Turn Display Menu Off and On
SoUn
oFF - on
Turn Sound Active Mode Off and On
CHnL
9CH
Set the Fixture to 9 Channel Mode
21CH
Set the Fixture to 21 Channel Mode
NAn
oFF - on
Control of all Features via Control Panel
ch.1 c000-c255
Pan Control
ch.2 c000-c255
Pan Fine Control
ch.3 c000-c255
Tilt Control
ch.4 c000-c255
Tilt Fine Control
ch.5 c000-c255
Speed Control of Built in Programs
ch.6 c000-c255
Dimmer (0% <-> 100%)
ch.7 c000-c255
Strobe (slow <-> fast)
ch.8 c000-c255
Random Strobe
(slow <-> fast)
ch.9 c000-c255
Auto Mode
DMX Mode
Allows the unit to be controlled by any universal DMX controller.
Set the DMX Starting Address:
1.) The default mode for the fixture is DMX, which appears as
d001
on the LED readout. To
select a different DMX address, using the
<MENU>
button, select
Addr
, then hit
<ENTER>
.
Use the
<UP/DOWN>
buttons to select the correct address, then hit
<ENTER>
to confirm.
Set the DMX Channel Mode:
1.) To select a DMX channel mode, press the
<MENU>
button, then use the
<UP/DOWN>
buttons until the display reads
CHnL
and press the
<ENTER>
button. Then use the
<UP/
DOWN>
buttons to select
9CH
and press
<ENTER>
for 9-channel mode, or select
21CH
and
press
<ENTER>
for 21-channel mode.
Master/Slave Mode:
1.) To set the fixture as the master fixture (default), press the
<MENU>
button to navigate to
SLnd
, then use the
<UP/DOWN>
buttons until the display reads
HoST.
Press the
<ENTER>
button to confirm. The master (host) is the first fixture in the DMX chain.
2.) To run the fixture as a slave, press the
<MENU>
button to navigate to
SLnd
, then use the
<UP/DOWN>
buttons until the display reads
SLAV.
Press the
<ENTER>
button to confirm.