background image

Blizzard Lighting, LLC

www.blizzardlighting.com

Waukesha, WI USA

Copyright (c) 2018

Summary of Contents for AtmosFEAR Big Bad Lo Fo

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2018...

Page 2: ...heostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Please verify that the unit is suitable for your local power supply See the unit s specifications for more information The lis...

Page 3: ...s Be sure that no air intake slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type DO NOT operate at ambient...

Page 4: ...you can add any type of water based fog liquid light standard heavy etc in order to give on the effect different dimension intensity and duration MAIN FEATURES DMX controllable water based low lying...

Page 5: ...rd Lighting s own Steam fog fluid products Step 3 Fill the water tank manually or via the water inlet connection Step 4 Connect the hoses to the output ducts Step 5 Connect the machine to suitable rat...

Page 6: ...e the water tank Note When filling the tank the water level needs to be covering the water level sensors by at least about 3 4 cm If there is not enough water in the tank the red warning LED near the...

Page 7: ...ated splitter may result in deterioration of the digital DMX signal The maximum recom mended cable run distance is 500 meters 1640 ft Data DMX Cabling To link units together you ll need data cables Yo...

Page 8: ...gher level menu item Value adjustment upward Value adjustment downward Is used to select and confirm store the current selection Starts or stops timer operation To navigate the control menu use the ME...

Page 9: ...ime in between timed fog outputs in sec onds while duration settings are used to control the actual period of time of the timed output in seconds while using timer mode 1 Press the MENU button repeate...

Page 10: ...it back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that i...

Page 11: ...r Consumption 1983W 19 1A PF 99 Fuse 15A 250V Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Operation Capacity Warm up Time 5 8 min Water Tank Capacity 13L Fluid Tank Capacity 2L Outpu...

Page 12: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...