background image

 

CAUTION: 

 

Do not move the unit by lifting either the door or door handles as this may cause damage 

to the cabinet. 

 

Do not use damaged appliances. If you are in any doubt, consult an engineer.

 

Connection and installation of your chiller are to be carried out in strict compliance with 

the relative instructions in this manual.

 

For safety, the appliance must be properly earthed in accordance with specifications

 

Do  not  damage  any  parts  of  the  appliance  which  carry  refrigerant  by  piercing, 

perforating, crushing, twisting or scraping. If the refrigerant comes into contact with the 

eyes, it may cause serious eye injury.

 

Always remember to unplug the appliance before cleaning. Never unplug your appliance 

by pulling on the power cable. Always grip plug firmly and pull straight out from the 

socket. Always check that the plug and cable are undamaged.

 

All  repairs  must  be  carried  out  by  qualified  engineers.  Inadequate  repairs  may  be 

dangerous. Never try to repair the refrigerator yourself.

 

Should the cover of the interior light or fan fall off or break, switch the refrigerator off 

immediately and replace the cover.

 

Ensure your chosen location has a flat and stable surface. The unit may be leveled by 

turning either or both of the adjustable feet in the front corners. Check the unit is level 

using a spirit level.

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent 

or similarly qualified persons in order to avoid hazard.

 

Be sure to leave at least 60mm of distance between the rear of the chiller and walls for 

ventilation, 30mm distance to be allowed above and to the sides for ventilation. 

 

Do not store explosive substances such as aerosol cans with a flammable propellant in 

this appliance. 

 

This appliance is intended for use indoor, such as shopping center, bar room

restaurant and so on, but not for household use. 

 

This appliance noise is less than 65dB. 

 

   Do not obstruct or cover the ventilation aperture. 

 

   Do not allow children to play with the appliance, or to sit on it or to hang onto the door. 

 

   Make  sure  there  is  a  suitable  power  Outlet  (220-240V/50Hz,  13  amps  outlet)  with 

proper grounding to power the refrigerator. 

 

This appliance can be used by children aged from 8 years and above and persons with     

reduced physical, sensory or mental capabilities or lack of experience and knowledge 

if they have been given supervision or instruction concerning use of the appliance in a 

safe way and understand the hazards involved. Cleaning and user maintenance shall not 

be made by children without supervision. 

 

Do  not  position  this  appliance  with  its  rear  panel  directly  against  a  wall.  For  good 

circulation  and  operating  efficiency,  the  ventilation  grilles  must  never  be  blocked. 

Ventilation should be provided above and to each side of the unit and must never be 

built into a cupboard.  
 
 

 

BEFORE USING FOR THE FIRST TIME 

Remove all packaging and place the chiller on a stable, secure flat surface. Position the chiller 

away from heat sources, where the unit is well-ventilated and protected from moisture, or 

extremes of heat or cold. The refrigerator may not function properly if the temperature rises 
above  +30 

℃ 

(standard  models).  The  refrigerator  is  designed  to  operate  in  an  ambient 

temperature of between 16 °C and 25°C however can operate for short periods (max 8 hours) 

at 32°C. Doors should be firmly closed during use and suitable for storing sealed containers, 

cans and bottles etc. 

A 13A fuse is fitted. Never replace with a fuse rated higher than this. 

NEVER  USE  AN  EXTENSION  LEAD

.  If  the  mains  cable  will  not  reach  the  nearest 

socket, either rearrange your store layout or ask a qualified electrician to fit a new socket. 

If power is cut off, wait for at least 5 minutes before plugging the unit in again to avoid 

damaging the compressor. 

Do not place combustible, explosive or volatile articles, corrosive acid or alkali, or liquid in 

glass containers into the chiller. Always exercise caution if adjusting the temperature. 

The maximum load for a shelf is 30Kg. 

PLUG IN 

Before the unit is plugged in leave it to stand upright in its location for at least one hour 

after transportation. Once plugged in, the display will show the temperature inside the 

chiller and the compressor will run after an initial pause (the indicator light of cooling will 

on at the same time). This temperature is the actual temperature recorded by the probes 

inside the chiller and as the chiller cools to the set point so the number on the display will 

descend accordingly. 

 

OPERATING FRONT PANEL DISPLAY 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Adjust set point:  

press 

Set

 for 2 seconds, set point will appear 

flashing on the display, press 

 to increase 

the set point, or press 

 to lower the set 

point.  
Press Set to save the new set point. 

Modifying parameters 
(technician only): 

Press Set for 3 seconds to 
access parameters, PS will be 
displayed, press set and use 
keys to enter password 22. 
scroll through parameters 
using arrows, select set to view 
and edit values using the arrow 
keys. 

Hold

 key for 3 seconds to 

initiate a defrost 

PS 

Password 

22 

dl 

interval between defrosts 

/5 

0=°C,1=°F 

dp 

defrost max duration 

20 

/6 

decimal point 1=disable 

d4 

defrost on 1st switch on 

/C1 

Probe Calibration 

d6 

disable temp during def 

St 

Set point 

A0 

Alarm diffeential 

-2 

rd 

differential 

AL 

Low temp alarm setting 

-5 

c0 

comp delay start 

AH 

High temp alarm setting 

15 

c1 

min time between starts 

Ad 

Alarm delay 

c4 

compressor safety duty  

15min 

H2 

Enable keypad 0=disabled 

d0 

0/1 defrost by temp. 2-4 

defrost by time 

EY 

restore default setting 

 

Summary of Contents for Bar10

Page 1: ...d of in an environmentally friendly way The cardboard may be used as scrap paper The protective foil and the foam cushions are CFC free Do not allow children to play with the packaging and destroy plastic bags safely Environmental protection Discarded electric appliances are recyclable and should not be discarded in the domestic waste Please actively support us in conserving resources and protecti...

Page 2: ... unit must be earthed If the power cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid hazard Ensure that the appliance is properly earthed Stop using the appliance immediately if electric shock is felt when touching the chiller WARNING Keep clear of obstruction all ventilation openings in the appliance enclosure or in the str...

Page 3: ...rd House Unit17 Walker Industrial Estate Walker Road Blackburn Lancashire BB1 2QE Tel 01254 614444 www pentlandwholesale co uk 5 DISPOSAL OF PACKAGING Do not allow children to play the packaging and destroy plastic bags safely The cardboard may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping foil is made of polyethylene The polyethylene pads and stuffi...

Page 4: ...iciency the ventilation grilles must never be blocked Ventilation should be provided above and to each side of the unit and must never be built into a cupboard 3 BEFORE USING FOR THE FIRST TIME Remove all packaging and place the chiller on a stable secure flat surface Position the chiller away from heat sources where the unit is well ventilated and protected from moisture or extremes of heat or co...

Reviews: