CAUTION:
Do not move the unit by lifting either the door or door handles as this may cause damage
to the cabinet.
Do not use damaged appliances. If you are in any doubt, consult an engineer.
Connection and installation of your chiller are to be carried out in strict compliance with
the relative instructions in this manual.
For safety, the appliance must be properly earthed in accordance with specifications
Do not damage any parts of the appliance which carry refrigerant by piercing,
perforating, crushing, twisting or scraping. If the refrigerant comes into contact with the
eyes, it may cause serious eye injury.
Always remember to unplug the appliance before cleaning. Never unplug your appliance
by pulling on the power cable. Always grip plug firmly and pull straight out from the
socket. Always check that the plug and cable are undamaged.
All repairs must be carried out by qualified engineers. Inadequate repairs may be
dangerous. Never try to repair the refrigerator yourself.
Should the cover of the interior light or fan fall off or break, switch the refrigerator off
immediately and replace the cover.
Ensure your chosen location has a flat and stable surface. The unit may be leveled by
turning either or both of the adjustable feet in the front corners. Check the unit is level
using a spirit level.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid hazard.
Be sure to leave at least 60mm of distance between the rear of the chiller and walls for
ventilation, 30mm distance to be allowed above and to the sides for ventilation.
Do not store explosive substances such as aerosol cans with a flammable propellant in
this appliance.
This appliance is intended for use indoor, such as shopping center, bar room
,
restaurant and so on, but not for household use.
This appliance noise is less than 65dB.
Do not obstruct or cover the ventilation aperture.
Do not allow children to play with the appliance, or to sit on it or to hang onto the door.
Make sure there is a suitable power Outlet (220-240V/50Hz, 13 amps outlet) with
proper grounding to power the refrigerator.
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Cleaning and user maintenance shall not
be made by children without supervision.
Do not position this appliance with its rear panel directly against a wall. For good
circulation and operating efficiency, the ventilation grilles must never be blocked.
Ventilation should be provided above and to each side of the unit and must never be
built into a cupboard.
3
BEFORE USING FOR THE FIRST TIME
Remove all packaging and place the chiller on a stable, secure flat surface. Position the chiller
away from heat sources, where the unit is well-ventilated and protected from moisture, or
extremes of heat or cold. The refrigerator may not function properly if the temperature rises
above +30
℃
(standard models). The refrigerator is designed to operate in an ambient
temperature of between 16 °C and 25°C however can operate for short periods (max 8 hours)
at 32°C. Doors should be firmly closed during use and suitable for storing sealed containers,
cans and bottles etc.
A 13A fuse is fitted. Never replace with a fuse rated higher than this.
NEVER USE AN EXTENSION LEAD
. If the mains cable will not reach the nearest
socket, either rearrange your store layout or ask a qualified electrician to fit a new socket.
If power is cut off, wait for at least 5 minutes before plugging the unit in again to avoid
damaging the compressor.
Do not place combustible, explosive or volatile articles, corrosive acid or alkali, or liquid in
glass containers into the chiller. Always exercise caution if adjusting the temperature.
The maximum load for a shelf is 30Kg.
PLUG IN
Before the unit is plugged in leave it to stand upright in its location for at least one hour
after transportation. Once plugged in, the display will show the temperature inside the
chiller and the compressor will run after an initial pause (the indicator light of cooling will
on at the same time). This temperature is the actual temperature recorded by the probes
inside the chiller and as the chiller cools to the set point so the number on the display will
descend accordingly.
OPERATING FRONT PANEL DISPLAY
4
Adjust set point:
press
Set
for 2 seconds, set point will appear
flashing on the display, press
to increase
the set point, or press
to lower the set
point.
Press Set to save the new set point.
Modifying parameters
(technician only):
Press Set for 3 seconds to
access parameters, PS will be
displayed, press set and use
keys to enter password 22.
scroll through parameters
using arrows, select set to view
and edit values using the arrow
keys.
Hold
key for 3 seconds to
initiate a defrost
PS
Password
22
dl
interval between defrosts
6
/5
0=°C,1=°F
0
dp
defrost max duration
20
/6
decimal point 1=disable
0
d4
defrost on 1st switch on
0
/C1
Probe Calibration
0
d6
disable temp during def
1
St
Set point
4
A0
Alarm diffeential
-2
rd
differential
3
AL
Low temp alarm setting
-5
c0
comp delay start
2
AH
High temp alarm setting
15
c1
min time between starts
2
Ad
Alarm delay
0
c4
compressor safety duty
15min
H2
Enable keypad 0=disabled
1
d0
0/1 defrost by temp. 2-4
defrost by time
2
EY
restore default setting
0