CLEANING 
 

1. UNPLUG your chiller and remove any stock to a suitable back-up chiller. 
2. Wash the inner compartment with warm water and neutral detergent. DO NOT allow the 
control panel, cables or plug to get wet. 
NEVER use corrosive detergents, wire brushes, or abrasive scourers to clean your chiller. 
NEVER use metal or sharp implements to remove debris. 
3. Dry all surface thoroughly. 
4. To ensure trouble-free operation the condenser should be cleaned every three months 
where appropriate using a vacuum hose. The condenser is located at the rear of the cabinet. In exceptionally 
dusty locations the condenser should be cleaned more often. 
5. Use mild soapy water to clean the gasket and seals. 

 

 

CORRECT USAGE 

1.  Never over load the cabinet, allow space free air movement around the products being stored inside, 

avoid loading products directly in front of the upper fan. 

2.  Manually record temperature logs once a day, record max and min temperature logs, reset max and 

min temp log after recording the values taken. 

3.  Avoid prolonged door openings, ensure door open time is kept to a minimum ensure door is closed 

properly 

4.  If the cabinet has been recently fully loaded, observe max temperature log, a brief high temperature 

alarm may be due to the excessive door open period. 

5.  If alarms have been triggered, escalate the readings to a responsible person as the medicine/vaccine 

may have been damaged. 

6.  The CR2450 battery in the thermometer has an estimated 3000-hour life  expectancy, the battery 

should be replaced in the thermometer approximately every 4 months.  

7.  The  Blizzard  MED140  has  been  validated  for  use  as  a  pharmacy  refrigerator  however  It  is 

recommended  that  you  have  independent  validation  of  the  cabinet  on  site  to  suit  your  individual 
requirements. 

 

 

 

 

Warranty 

Should you encounter any problems during the warranty period, please check the power supply and fuses, 
installation and use before placing a service call request to your supplier. 

The warranty supplied with the unit will cover the repair of faults due to component failure during the stated 
warranty period. The warranty excludes consumable items like bulbs, gaskets, batteries etc. and any faults 
relating to incorrect installation, maintenance or use.  

 

 

 

 

 

 

 

 
 

DISPOSAL OF PACKAGING 
 

Do not allow children to play the packaging, and destroy plastic bags safely. 
The cardboard may be broken or cut into smaller pieces and given to a waste paper disposal 
service. The wrapping foil is made of polyethylene. The polyethylene pads and stuffing 
contain no fluorochloric hydrocarbons. 
 
All these valuable materials may be taken to a waste collecting depot and used again after 
adequate recycling. Consult your local authority for the name and address of the waste paper 
disposal services nearest to you. 
 
 
 
 
 
 

IMPORTANT SAFETY INSTRUCTIONS 
 
 

Before switching on your chiller for the first time, read the information in this user manual 
carefully. The manual contains important observations relating to the assembly, operation 
and maintenance of the appliance. 
 
Please keep this booklet in a safe place for future reference. If you ever sell your chiller, hand 
this user manual to the new owner. 
 
The manufacture does not accept responsibility for any damages that may arise due to non-observation 
of these instructions. The user is liable for any material damage or bodily injury 
(product liability) cause by using the refrigerator carelessly or failing to follow instructions. 

 

 

 

The manufacturer does not know what purpose you the end user, will use the product for or what items you 
will  store  in  or  monitor  with  it,  therefore  we  cannot  be  responsible  for  the  stored  content.  We  strongly 
recommend that you insure the stored materials for any consequential loss which may arise from a fault in 
the product. 

 

 

 

 

 

 

 

 

Summary of Contents for MED140

Page 1: ...n an environmentally friendly way The cardboard may be used as scrap paper The protective foil and the foam cushions are CFC free Do not allow children to play with the packaging and destroy plastic bags safely Environmental protection Discarded electric appliances are recyclable and should not be discarded in the domestic waste Please actively support us in conserving resources and protecting the...

Page 2: ...ss by insisting on an appropriate non polluting method of disposal WARNING RISK OF ELECTRICAL SHOCK HAZARD This unit must be earthed If the power cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid hazard Ensure that the appliance is properly earthed Stop using the appliance immediately if electric shock is felt when touching ...

Page 3: ...hould you encounter any problems during the warranty period please check the power supply and fuses installation and use before placing a service call request to your supplier The warranty supplied with the unit will cover the repair of faults due to component failure during the stated warranty period The warranty excludes consumable items like bulbs gaskets batteries etc and any faults relating t...

Page 4: ...e refrigerator may not function properly if the temperature rises above 30 standard models The refrigerator meets the operating conditions according to climate class 4 A 13A fuse is fitted Never replace with a fuse rated higher than this NEVER USE AN EXTENSION LEAD If the mains cable will not reach the nearest socket either rearrange your store layout or ask a qualified electrician to fit a new so...

Reviews: