Solar Cell™ User Manual - Rev. A    

 

(c) 2016 Blizzard Lighting, LLC

3. SETUP

Fuse Replacement

CAUTION!

  The Solar Cell™ utilizes a high-output switch-mode power 

supply with an internal fuse. Under normal operating conditions, the 

fuse should not require replacement. The fuse is field replaceable, 

however it is an advanced procedure suited to qualified individuals.  

Should your Solar Cell™ fuse require replacement, please contact 

Blizzard Lighting for instructions, or to return your unit for service.

Connecting A Bunch of Solar Cell™ Fixtures

You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fixtures set to sync in master/

slave operating mode. The combined number of channels required by all 

the fixtures on a serial data link determines the number of fixtures the 

data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fixtures on one serial data link without 

the use of a DMX optically-isolated splitter may result in deterioration of 

the digital DMX signal. The maximum recommended cable-run distance 

is 500 meters (1640 ft).  The maximum recommended number of 

fixtures on a serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but 

note that they cannot transmit DMX data as reliably over long distances.  

In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Summary of Contents for SOLAR CELL

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2016 SOLAR TM...

Page 2: ...7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Contro...

Page 3: ...the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefu...

Page 4: ...VER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEV...

Page 5: ...mpact high quality housing CONTROL USITT DMX 512 2 6 channel DMX modes Standalone auto master slave sound active modes 3 pin DMX input and output Easy to use 4 button LED control panel DMX Values In D...

Page 6: ...r Cell Pin Up Picture Manual 20 Pendulum Angle Adjustment with Locking Knobs 2 100W 3200 3500K Warm White LEDs Figure 2 The Rear Connections Mounting Bracket with Locking Knobs Safety Cable Loop 4 but...

Page 7: ...s on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deteri...

Page 8: ...like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No...

Page 9: ...he fixtures that follow may also re quire a slave setting Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging Th...

Page 10: ...scending order DOWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The control panel LED display shows the menu items you se...

Page 11: ...rom 001 to 512 3 Press the ENTER button to confirm Master Slave Mode 1 This fixture does not require additional settings to run as a slave The first fixture linked in the DMX chain will serve as the m...

Page 12: ...e ENTER button to confirm your choice Dimming Mode Selection 1 Navigate the main menu until you reach dEL then press ENTER 2 Use the UP DOWN buttons to highlight a selection ranging from dEL0 no dimmi...

Page 13: ...t DMX provides up to 512 control channels per data link Each of these channels was originally intended to control lamp dimmer levels You can think of it as 512 faders on a lighting console connected t...

Page 14: ...w factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for servi...

Page 15: ...C ambient Control Protocol USITT DMX 512 DMX Channels 6 2 channels Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Mode Other Information My Ne...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: