background image

Fig. 4. Drainage installation. 6 
Fig. 5. Installation of drainage at a height using drainage pump. 

The drainage pump must only be installed by personnel authorised by the 
manufacturer, and the manufacturer does not accept liability in the event of 
incorrect installation. 

4.6 Mechanical rinse aid dispenser 

Operation: This dispenser absorbs the rinse aid when it detects a loss in pressure during rinsing. 
That is, when the filling solenoid valve closes, a vacuum is created that makes the rinse aid dispenser 
absorb the fluid to which it is connected. 
Adjustment: The dispenser should be adjusted when the machine is installed to ensure that the 
wash is optimised from the start. The setting should be adjusted according to the type of rinse aid 
and the water hardness. 

4.7 Detergent dispenser 

This ensures that the correct measure of detergent is supplied to the machine. 
Installation: the detergent dispenser input must be in the tub of the machine, below the maximum 
water level. Please see the electrical circuit diagram for details of the electrical connection The tub 
has an opening for the installation of the dispenser. 
Operation: the detergent dispenser is activated when the machine is taking water, whether it is in 
rinse cycle or whether it is filling. 
Settings: the measure of detergent used should be adjusted when the component is installed to 
ensure that the wash is optimised from the start. 

The manufacturer recommends that the detergent and the dispenser setting are defined 
by a technician specialised in the use of chemical products in order to ensure a more  
efficient wash. 

4.8 Pressure pump 

If the mains water pressure is less than 2 bar (200 kPa), you have the option of installing a pressure 
pump. If the pressure is less than 2 bar (200kPa), the machine may operate incorrectly. The 
electrical connections for the pressure pump are shown in the electric circuit diagram. The water 
connection to the pressure pump is shown in Fig. 3. 
If the mains water pressure is less than 2 bar (200 kPa), please contact your supplier or the 
manufacturer to request the PRESSURE PUMP KIT. 

The pressure pump must only be installed by personnel authorised by the manufacturer, 
and the manufacturer does not accept liability in the event of incorrect installation 

 

 

 

5. USE AND MAINTENANCE INSTRUCTIONS 

BEFORE STARTING THE APPLIANCE, PLEASE READ THE INSTRUCTIONS 
CONTAINED IN THIS MANUAL CAREFULLY. 
THE APPLIANCE IS EXCLUSIVELY FOR PROFESSIONAL USE, AND SHOULD 
ONLY BE USED BY QUALIFIED PERSONNEL. 

5.1 Operation 

The steps required to optimise the operation of your dishwasher are shown below, with all the available 
options. 

5.1.1 Control panel symbols Fig. 7 

A. Machine on/off button. (ON/OFF) / Machine on pilot light 
B. Machine ready pilot temperature satisfied 
C. Short cycle button (90 s)/ Drainage button / Machine working pilot 
D. Medium cycle button (120 s) / Machine working pilot 
E. Long cycle button (180 s) / Cold rinse button / Machine working pilot 
 

 

 

 

Summary of Contents for Storm Series

Page 1: ...asswasher User Manual Read these instructions carefully before using your Glasswasher and care for it properly If you follow the instructions your glasswasher will provide you with many years of good...

Page 2: ...Fig1 Dimensions mm Storm 35 35DP Storm 40 40DP...

Page 3: ...Drain pump versions...

Page 4: ...the basket open the door and insert basket close door Press and release the cycle button relating to the length of wash required the cycle button will illuminate when a cycle is in action The cycle l...

Page 5: ...should be correctly levelled and care taken to ensure that none of the electric cables water or drainage hoses are trapped or kinked DO NOT climb on top of the dishwasher or place heavy objects on to...

Page 6: ...ECIFICATIONS PLATE 1 APPLIANCE MODEL NAME 2 APPLIANCE REFERENCE 3 SERIAL NUMBER MANUFACTURE DATE 4 ELECTRICAL SPECIFICATIONS 5 WATER INLET SPECIFICATIONS These details should be quoted when the techni...

Page 7: ...onnection An AUTHORISED TECHNICIAN should always carry out the appliance s electrical connection The legal standards in force in each country regarding connection to the mains should be taken into acc...

Page 8: ...should be mounted at the mains water supply Fig 3 It is not necessary to install a pressure pump in the BT models Fig 2 Direct connection of water input hose Fig 3 Pressure pump connection S SHUT OFF...

Page 9: ...the wash is optimised from the start The manufacturer recommends that the detergent and the dispenser setting are defined by a technician specialised in the use of chemical products in order to ensur...

Page 10: ...that mentioned above due to heating inertia This is normal If pressurised steam is observed coming out of the rinse branch nozzles while the boiler is heating the technical service should be notified...

Page 11: ...e switched off during the wash process as this will stop the tableware inside the machine from being cleaned properly 5 1 11 Cleaning the machine at the end of the day At the end of the day the filter...

Page 12: ...ommends you proceed as follows Wash the dishes when the machine is ready Always ensure the different dispensers are correctly adjusted Keep the dishwasher thoroughly clean 5 2 5 Prolonged non use If t...

Page 13: ...hes and kitchenware are not dry There is no rinse aid Fill the rinse aid container Rinse aid low Adjust rinse aid intake Dishes left inside dishwasher for too long When the dishwasher finishes remove...

Page 14: ...components Consult your local waste collection authority regarding disposal of your appliance Local authorities are not obliged to dispose of commercial equipment but may be able to offer advice on ho...