Fig. 4. Drainage installation. 6
Fig. 5. Installation of drainage at a height using drainage pump.
The drainage pump must only be installed by personnel authorised by the
manufacturer, and the manufacturer does not accept liability in the event of
incorrect installation.
4.6 Mechanical rinse aid dispenser
Operation: This dispenser absorbs the rinse aid when it detects a loss in pressure during rinsing.
That is, when the filling solenoid valve closes, a vacuum is created that makes the rinse aid dispenser
absorb the fluid to which it is connected.
Adjustment: The dispenser should be adjusted when the machine is installed to ensure that the
wash is optimised from the start. The setting should be adjusted according to the type of rinse aid
and the water hardness.
4.7 Detergent dispenser
This ensures that the correct measure of detergent is supplied to the machine.
Installation: the detergent dispenser input must be in the tub of the machine, below the maximum
water level. Please see the electrical circuit diagram for details of the electrical connection The tub
has an opening for the installation of the dispenser.
Operation: the detergent dispenser is activated when the machine is taking water, whether it is in
rinse cycle or whether it is filling.
Settings: the measure of detergent used should be adjusted when the component is installed to
ensure that the wash is optimised from the start.
The manufacturer recommends that the detergent and the dispenser setting are defined
by a technician specialised in the use of chemical products in order to ensure a more
efficient wash.
4.8 Pressure pump
If the mains water pressure is less than 2 bar (200 kPa), you have the option of installing a pressure
pump. If the pressure is less than 2 bar (200kPa), the machine may operate incorrectly. The
electrical connections for the pressure pump are shown in the electric circuit diagram. The water
connection to the pressure pump is shown in Fig. 3.
If the mains water pressure is less than 2 bar (200 kPa), please contact your supplier or the
manufacturer to request the PRESSURE PUMP KIT.
The pressure pump must only be installed by personnel authorised by the manufacturer,
and the manufacturer does not accept liability in the event of incorrect installation
5. USE AND MAINTENANCE INSTRUCTIONS
BEFORE STARTING THE APPLIANCE, PLEASE READ THE INSTRUCTIONS
CONTAINED IN THIS MANUAL CAREFULLY.
THE APPLIANCE IS EXCLUSIVELY FOR PROFESSIONAL USE, AND SHOULD
ONLY BE USED BY QUALIFIED PERSONNEL.
5.1 Operation
The steps required to optimise the operation of your dishwasher are shown below, with all the available
options.
5.1.1 Control panel symbols Fig. 7
A. Machine on/off button. (ON/OFF) / Machine on pilot light
B. Machine ready pilot temperature satisfied
C. Short cycle button (90 s)/ Drainage button / Machine working pilot
D. Medium cycle button (120 s) / Machine working pilot
E. Long cycle button (180 s) / Cold rinse button / Machine working pilot