1

BCH-E

ELECTRIC CABINET BASED BRAISING PAN WITH

HEAVY DUTY HYDRAULIC TILT

INSTALLATION – OPERATION – MAINTENANCE

BLODGETT OVEN COMPANY

www.blodgett.com

44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone (800) 331-5842, (802) 860-3700 Fax: (802) 864-0183

S00066 Rev A (5/04)

Summary of Contents for BCH-30E

Page 1: ...AISING PAN WITH HEAVY DUTY HYDRAULIC TILT INSTALLATION OPERATION MAINTENANCE BLODGETT OVEN COMPANY www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 800 331 5842 802 860 3700 Fax 802 864 0183 S00066 Rev A 5 04 ...

Page 2: ...symbol to avoid possible injury or death WARNING Improper installation operation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing operating or servicing this equipment This manual should be retained for future reference Intended for commercial use only Not for household u...

Page 3: ...and Operation 2 2 0 Service Connections 4 3 0 Installation Instructions 5 4 0 Operation Instructions 8 5 0 Cleaning Instructions 10 6 0 Cooking Guidelines 11 7 0 Maintenance Hydraulic System 15 8 0 Adjustments Pan Speed 16 9 0 Troubleshooting 17 Material Safety Data Sheet 20 ...

Page 4: ...5 50 0 41 6 1 3 1 3 3 81 8 47 2 68 2 39 4 31 5 N A N A 27 3 22 8 18 2 75 0 43 3 62 5 36 1 28 9 N A 25 0 N A 20 9 16 7 AMPS PER LINE 57 7 208V PHASE 1 220V 54 5 380V 50 0 240V 415V N A N A 21 7 N A 18 0 14 4 480V ELECTRICAL RATINGS 2 5 64 27 686 4 102 MINIMUM 23 5 597 POUR PATH C A 3 76 33 838 37 940 E D B 28 711 40 5 1029 6 152 7 5 190 REAR FLANGED FOOT DETAIL 2 7 16 11mm HOLES ON 2 5 763 B C EQUA...

Page 5: ... The installation location must allow adequate clearances for servicing and proper operation A minimum front clearance of 36 and rear clearance of 4 is required INSTALLATION CODES AND STANDARDS Your Blodgett Tilting Braising Pan must be installed in accordance with 1 In Canada provincial and local codes or in the absence of local codes with C S A C22 1 Canadian Electrical Code Part 1or in the U S ...

Page 6: ...choring holes provided in the rear flanged adjustable feet 4 Remove tilting braising pan from installation position and drill holes in locations marked on the floor See installation diagram on page 4 Insert proper anchoring devices not supplied 5 Place tilting braising pan back in the installation position 6 Place carpenter s level on top of braising pan and re level side to side and front to back...

Page 7: ...wiring diagram located inside the control housing cover panel The braising pan must be grounded in accordance with requirements of the National Electrical Code or applicable local codes Connection from incoming lines must be waterproof 2 Ground skillet to terminal provided in control housing A wiring diagram is provided and is located inside the control cover panel 3 Replace wiring compartment cov...

Page 8: ...SWITCH Push up to raise tilting braising pan push down to lower tilting braising pan POWER SWITCH Turns power on to the lift motor Note it is not necessary to have the power on when using the braising pan Turn power on only when you intend to operate the tilt feature This will save energy as well as prevent the motor from overheating AMBER LIGHT Will light when the power is turned on to the lift m...

Page 9: ...e 7 Turn power switch to motor OFF DAILY SHUTDOWN PROCEDURE To turn tilting braising pan off turn THERMOSTAT dial to OFF To turn power to tilt motor off turn power switch to OFF TILTING THE BRAISING PAN 1 DO NOT try to tilt braising pan with lid down 2 Turn power switch to the ON position 3 Make sure the receiving pan is in place 4 To tilt braising pan push and hold TILT SWITCH in the UP mode unti...

Page 10: ...times Do not get water in electrical box or on any electrical component 1 Thoroughly wash pan pouring spout see Figure 2 lid and exterior surfaces with mild detergent and warm water If necessary soak pan to remove food that is stuck to pan surface Rinse thoroughly and wipe dry with a soft clean cloth 2 Clean removable strainer and receiving pan support with mild detergent and warm water Rinse thor...

Page 11: ... Bacon 3 slices 350 12 2 lbs 10 3 lbs 15 Eggs Boiled Hard 1 egg 225 5 50 eggs 50 75 eggs 75 Boiled Soft 1 egg 225 8 50 eggs 50 75 eggs 75 Fried 1 egg 400 4 30 eggs 30 45 eggs 45 Poached 1 egg 225 5 36 eggs 36 60 eggs 60 Scrambled 1 1 2 eggs 300 200 1 18 gal 720 28 gal 1100 French Toast 3 slices 450 7 35 slices 12 50 slices 17 Regular Oatmeal cup 250 2 20 lbs 100 cups 500 40 lbs 200 cups 1000 Panca...

Page 12: ...125 40 lbs 200 Cabbage 3 oz 400 5 20 lbs 80 30 lbs 125 Carrots 3 oz 400 2 35 lbs 150 70 lbs 300 Cauliflower 3 oz 250 5 15 lbs 75 25 lbs 125 Corn 1 ear 400 8 50 ears 50 75 ears 75 Potatoes 3 oz 400 2 40 lbs 200 60 lbs 300 Spinach 4 oz 250 10 6 lbs 25 9 lbs 35 Turnips 4 oz 400 2 20 lbs 100 30 lbs 150 FROZEN Beans French Green 3 oz 400 6 15 lbs 60 22 1 2 lbs 90 Lima Beans 3 oz 250 4 15 lbs 60 22 1 2 ...

Page 13: ...5 gal 560 Corned Beef Hash 5 oz 400 5 16 lbs 50 25 lbs 75 Cheeseburger 3 oz 300 12 7 lbs 35 10 lbs 50 Hamburger 3 oz 300 15 7 lbs 35 10 lbs 50 Meatballs 1 oz 400 225 3 12 1 2 lbs 65 18 lbs 100 Pot Roast 2 oz 350 200 120 lbs 500 180 lbs 750 Salisbury Steak 5 oz 400 3 16 lbs 50 24 lbs 75 Sirloin Steak 6 oz 400 5 15 lbs 40 22 1 2 lbs 60 Swiss Steak 4 oz 300 200 1 25 lbs 110 40 lbs 160 CHICKEN Pan Fri...

Page 14: ...2 oz 400 200 3 26 30 lbs 200 4 26 30 lbs 275 On Carcass 2 oz 400 200 4 16 20 lbs 175 6 16 20 lbs 265 MISCELLANEOUS Grilled Cheese Sandwich 1 sandwich 400 8 35 sandwiches 35 50 sand 50 Macaroni Cheese 8 oz 200 2 18 gal 300 35 gal 525 Rice 4 oz 350 225 1 20 lbs raw 320 40 lbs raw 650 Spaghetti 4 oz 350 225 2 8 lbs raw 200 12 lbs raw 300 ...

Page 15: ...NANCE 1 Hot oil in the Hydraulic System is one of the primary causes of poor operation When the tilt system is not in use turn power switch off 2 Inspect hydraulic hoses for wear and aging 3 Check that fluid levels are kept full 4 To replace oil fill through filler breather 5 Use proper oil as specified by factory TYPE AWH32 or equivalent 6 Set up regular schedule for checking the oil temperature ...

Page 16: ...he cylinder fully and thus deadhead the system The pressure can be set as indicated above When adjustment is complete replace the hexagon cover This will seal the relief valve area The actual factory set pressure is noted on the label and should not be exceeded as this affects the HP draw on the electric motor FLOW CONTROL There are two flow control valves mounted on the power unit and located on ...

Page 17: ...contactors BRAISING PAN WILL NOT OPERATE UP OR DOWN 1 Power supply not ON 2 Defective UP DOWN switch 3 SEE TROUBLESHOOTING HYDRAULICS below TROUBLESHOOTING HYDRAULICS 1 DIRTY OIL a Components not properly cleaned after servicing b Inadequate screening in fill pipe c Air breather left off d Filter dirty or ruptured 2 FOAMING OIL a Return of tank line not below fluid level b Fluid contamination c Su...

Page 18: ... g Power unit operating in direct sunlight or ambient temperature is too high 5 PUMP MAKES EXCESSIVE NOISE a Check for vacuum leaks in suction line b Vacuum leak at pump shaft seal c Check alignment with drive mechanism Misalignment will cause wear and subsequent high noise level operation d Relief valve set too high e Aeration of fluids in reservoir return line above fluid level f Worn cam ring d...

Page 19: ...19 6 SOLENOID VALVES a Voltage too low b Short circuit open connection c Wrong voltage d Foreign matter in fluid causing valves to stick or plug ...

Page 20: ... the IDL regulations SECTION III PHYSICAL DATA Boiling Point Degree Fahrenheit 300 Specific Gravity Water 1 0 91 Vapour Pressure mmHg 1 Evaporation Rate BuAcr 1 1 Vapour Density Air 1 1 Percent Volatile Nil Soluble in Water Insoluble pH Neat Not Applicable Appearance and Odour Slightly hazy amber liquid with a bland odour SECTION IV FIRE AND EXPLOSION HAZARD DATA Flash Point Degrees Fahrenheit 520...

Page 21: ...r 15 minutes Consult physician Ingestion Induce vomiting Give liquids Consult physician Product contains fatty acid ester Note to Physicians No specific antidote known Based on individual reactions of the patient the physician s judgement should be used to control symptoms and clinical conditions SECTION VI REACTIVITY DATA Stability Stable X Unstable Incompatibility Materials to Avoid Strong Oxidi...

Page 22: ...handling ADDITIONAL PRODUCT INFORMATION Carcinogens as Defined By NTP None IARC None OSHA None Cercla Reportable Quantity Ibs None RCRA Hazardous Waste Number Not Applicable CEPA All components of this product are listed on the Domestic Substances List DSL as encoded in the extract of the Canada Gazette Part I SARA Title III Section 313 This product contains no toxic chemicals subject to the repor...