16
7.0 MAINTENANCE
NOTICE: Contact the factory, factory representative or local service company
to perform maintenance and repairs.
WARNING: The tilting braising pan and its parts are hot. Use care
when operating, cleaning and servicing the tilting braising pan.
WARNING: Disconnect the power supply to the appliance before
cleaning or servicing.
HYDRAULIC SYSTEM
SERVICE
Set up regular schedule for checking the oil temperature, hydraulic hoses and keeping
the equipment clean. A thick layer of dirt acts as an insulation and prevents the
hydraulic system from getting rid of heat.
The hydraulic system has been adjusted and tested at the factory and no further
adjustment should be needed. If the unit fails to operate properly, all service work must
be performed by a qualified service agent.
1. Hot oil in the Hydraulic System is one of the primary causes of poor operation.
When the tilt system is not in use turn POWER switch off.
2. Inspect hydraulic hoses for wear and aging.
3. Check that fluid levels are kept full.
4. To replace oil, fill through filler breather.
5. Use proper oil as specified by factory. TYPE: AWH32 or equivalent.
6. Check the cleanliness of the oil strainer inside the reservoir once per year. This item
can be washed in clean Varsol.
7. Change the breather filter once per year.
8. Change the oil once every two years.