Installation
9
Electrical Connections
Before making any electrical connections to these
units, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating name plate mounted on the
right side of the unit.
Wiring diagrams are located on the inside of the
louvered side panel.
NOTE: DISCONNECT THE POWER SUPPLY TO
THE UNIT BEFORE SERVICING!
U.S. and Canadian installation
All units, when installed, must be electrically
grounded in accordance with local codes or in the
absence of local codes, with the
National Electrical
Code, ANSI/NFPA 70-Latest Edition and/or CanaĆ
dian Electrical Code CSA C22.1
as applicable.
General Export Installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011Ć802Ć860Ć3700.
NOTE: ALL MANUAL RESETS SHOULD BE REĆ
STORED BEFORE CONNECTING POWER
TO THE APPLIANCE.
WARNING!!
Improper electrical installation will invaliĆ
date your warranty.
On 480V units, the convection fans should be
checked to ensure the proper rotation after conĆ
necting the appliance. See Figure 4. If the fans
turn in the wrong direction, the appliance will not
function properly and damage to the unit can ocĆ
cur. Improper connection of the appliance renders
the warranty invalid.
Direction Of Blower Wheel Rotation
Figure 4