Installation
5
Owner's Responsibilities
1. Oven(s) are uncrated and put in place.
2. The owner/operator must have the following
plumbing, gas and electrical requirements
met and installed.
NOTE: Refer to the Utility Connection inforĆ
mation provided.
WARNING!!
Improper installation, adjustment, alterĆ
ation service or maintenance can cause
property damage, injury or death. Read
the installation, operation and mainteĆ
nance instruction thoroughly before inĆ
stalling or servicing this equipment.
ELECTRICAL - COSĆ20E
Electrical
61kw
Amp/Line (max)
Volt
3 Phase
1 Phase
208
170
N/A
240
147
N/A
480
74
N/A
By Mode
Steam
45kw
y
Hot Air
60kw
Combi
60kw
Blower Motor
1 hp / 1 kw
PLUMBING - COSĆ20E
Water
Water Pressure (min/max)
40 PSI min/50 PSI max
Hot & Cold Water Connection
3/4" Hose Fitting, 3/8" ID hose minimum
Pressure Regulator Setting
35 PSI Preset
Minimum Requirements
TDS - less than 100 parts per million
Total Hardness - 80Ć120 parts per million
Chlorides -less than 30 parts per million
pH Factor - 7.0Ć8.0
Drainage
Atmospheric Vented Drain
Drain Connection
2" NPT
Avg Water Drain Temp.
122
_
F (50
_
C)