background image

SN-3E & SN-5E

ELECTRIC COUNTER CONVECTION STEAMER

INSTALLATION  - OPERATION - MAINTENANCE

42 Allen Martin Drive, Essex Junction, Vermont 05452 USA
Telephone: (802) 658-6600 Fax: (802) 864-0183

www.blodgett

 

PN S00059 Rev E (8/18) 

© 2018 - G.S. Blodgett Corporation

Summary of Contents for SN-3E

Page 1: ...COUNTER CONVECTION STEAMER INSTALLATION OPERATION MAINTENANCE 42 Allen Martin Drive Essex Junction Vermont 05452 USA Telephone 802 658 6600 Fax 802 864 0183 www blodgett PN S00059 Rev E 8 18 2018 G S...

Page 2: ...Your Service Agency s Address Model Serial number Steamer installed by Installation checked by...

Page 3: ...o Not Come On 13 Unit Shuts Down While in Operation 13 IMPORTANT WARNING Improper installa tion adjustment alternation service or maintenance can cause property damage in jury or death Read the instal...

Page 4: ...IONS Drain 1 25mm IPS piped to open floor drain No solid connection 24 length before open air opening no bends or elbows Cold Water 3 8 10mm tubing at 25 50 PSI 170 345 kPa The drain piping must consi...

Page 5: ...optional 4 adjustable legs are used remove the four levelling feet on the bottom of the steamer FEET Levelling Feet standard or 4 Adjustable Legs Op tional Thread the four 2 levelling feet shipped in...

Page 6: ...ype drain Drain pipe should be copper DO NOT use PVC pipe PVC pipe may lose its rigidity or glue may fail Adjusting Screw Figure 3 WATER QUALITY The water supply connected to this steamer should con t...

Page 7: ...echanical connec tions have been made thoroughly test the steamer before operation 1 Check that proper water drain and electrical connec tions have been made 2 Turn main power switch ON After approxim...

Page 8: ...At the end of the cooking cycle the COOKING light goes off the buzzer sounds and steam stops being supplied to the cooking chamber To stop the buzzer turn the timer to OFF SHUTDOWN Turn the main power...

Page 9: ...lly thaw overnight in a refrigerator This will reduce their cooking time PREPARATION Prepare vegetables fruits meats seafood and poultry normally by cleaning separating cutting removing stems etc Cook...

Page 10: ...lid pan cover pasta with cold water Spaghetti Regular Vermicelli Macaroni Shells Elbows Noodles wide Lasagna Noodles 12 15 15 18 12 15 15 18 Frozen Casseroles Lasagna 35 Full Pan Meat Loaf 3 5 pounds...

Page 11: ...1 6 Cut 8 5 lb Carrots Baby Whole Frozen Crinkle Cut Frozen Sliced Fresh 8 7 8 11 7 lb 4 lb 9 lb Cauliflower Florets Frozen Fresh 6 7 8 6 7 8 Celery 1 Diagonal Cut 7 5 lb Corn Yellow Whole Kernel Fro...

Page 12: ...water with a cloth or sponge to clean exposed bead of door gasket rinse with warm clear water and wipe with a dry cloth 5 Wipe surfaces which touch door gasket with a cloth or sponge and warm soapy w...

Page 13: ...ces of lime that will not flush out drain Should the tank cover have to be removed check condi tion of sealing gasket before replacing cover The hold down bolts are to be tightened to 160 inch pound t...

Page 14: ...hrenheit just below water boiling point Howev er for high altitude locations an authorized servicer must adjust the steamer temperature lower To adjust 1 Remove side panel and turn control panel power...

Page 15: ...probes check visually and clean or chip off scalant Replace probe This problem is an indication of severe harmful water conditions which should be corrected immediately to avoid damage to the componen...

Reviews: