Troubleshooting
No
Issue
Check and Resolve
1
Low/No water flow
from filter
-
Water supply is closed.
-
Temporarily water shortage in the area.
-
Filter inlet valve is closed.
2
Low/No water
pressure from filter
-
Water supply is closed.
-
Temporarily water shortage in the area.
-
Filter inlet valve is closed.
3
Abnormal filtrate
colour or taste
-
Flush the UF cartridge line individually for 3minutes
& check the filtrate with a transparent glass after it
stays for 30seconds. Continuous flushing if abnormal
filtrate colour/taste found except water bubble.
-
Flush Carbon cartridge line with UF water for
3minutes & check the filtrate with a transparent
glass. Continuous flushing if abnormal filtrate colour
found.
4
Pressure gauge shows
> 3bars
-
Reduce opening of the filter inlet valve to pressure <
3bars.
5
No figure shows on
display when button is
pressed
-
Check button battery (CR2032) position.
-
Replace battery if no figure shows after battery
repositioned.
6
No green LED lights
when button is
pressed
-
Check button battery (CR2032) position.
-
Replace battery if no figure shows after battery
repositioned.
7
Unable to reset
counter’s display to
“365” or to turn off the
buzzer.
-
Remove & reinstall all batteries.
8
Water leaking from
the filter
-
Open the Front Cover with care to identify the leaking
location.
-
Remove & reconnect the tubing to the fitting if
leaking from the tubing connection.
-
Others, please contact Blöndal customer careline for
rectification method.
Note:
Should any of the above issue persist after rectification, kindly contact Blöndal customer
careline at below contact for assistance
-
Malaysia:
+1300 88 0123 (Hotline) or +603 5569 1888
-
Singapore: +65 6741 7277
-
Brunei:
+673 2336 788
or chat with us via our live chat page at