200
Highlights of FCC Rules & Regulations Part 76
Standard
± 170 ns
Number Of Channels 4 channels minimum, plus 1 channel for
every 100 MHz or fractional increase:
5 Channels/54-216 MHz
6 Channels/54-300 MHz
7 Channels/54-400 MHz
8 Channels/54-500 MHz
Frequency Of Testing once every 3 years Testing
Type Of Equipment
Vectorscope, waveform monitor, or
automated test system
Rule
76.605 (a)(11)(i) Chrominance
Luminance Delay
Standard
Not to exceed ± 20%
Number Of Channels 4 channels minimum, plus 1 channel
for every 100 MHz or fractional increase
5 Channels/54-216 MHz
6 Channels/54-300 MHz
7 Channels/54-400 MHz
8 Channels/54-500 MHz
Frequency Of Testing once every 3 years Testing
Type Of Equipment
Vectorscope, waveform monitor, or
automated test system
Rule
76.605 (a)(11)(ii) Differential Gain
Summary of Contents for AMM-806
Page 86: ...79 TVCB PC Installation ...
Page 93: ...86 SMI Installation Torque Patterns 1 Start Here 2 3 4 5 6 1 Start Here 2 3 4 4 PORT 8 PORT ...
Page 125: ...118 Fiber Optics Fiber Loss vs Path Length Single Mode 1550 nm ...
Page 156: ...149 Cable TV Channel Format NTSC NTSC Composite Video Waveform ...
Page 157: ...150 US Frequency Spectrum ...
Page 158: ...151 FCC Aeronautical Band Frequencies Used for Communication and Navigation ...
Page 175: ...168 Common CATV Symbols ...
Page 176: ...169 Common CATV Symbols ...
Page 177: ...170 Digital L Band Distribution Symbols ...
Page 178: ...171 Digital L Band Distribution Symbols ...
Page 183: ...176 Typical Cable Attenuation Chart in dB 100 Feet 68 F 20 C ...
Page 187: ...180 Echo Rating Graph ...
Page 188: ...181 Signal to Interference Limits Non Coherent Carriers ...
Page 190: ...183 Heterodyne Modulator Analog ...
Page 191: ...184 Heterodyne Processor Analog ...
Page 213: ...206 Multiplexers ...
Page 285: ...Rev 8 0 ...