2 Clearview NTSC16

Quick Guide

Product Introduction

The 

Clearview NTSC16

 is a cutting-edge 1RU, multi-channel digital to RF analog synthesizer, designed to convert up to 16 HD 

or SD programs and the primary audio channel to 16 NTSC modulated RF analog channels. 

 

 

The 

Clearview NTSC16

 can input MPEG-2, MPEG-4/H.264 (AVC), or H.265 (HEVC) formats from an IP transport stream. Each 

IP MPEG transport stream is decoded, NTSC synthesized, and modulated to an STD, IRC, or HRC RF analog channel. All 16 

NTSC channels are agile within a 208 MHz frequency block. Users may place the 208 MHz block anywhere within the 54 to 

1002 MHz frequency span.

Features:

• 

Creates a 16 NTSC RF analog modulated channel lineup

• 

Decodes MPEG-2, H.264, and H.265 video content

• 

Dolby® Digital AC3, AAC, MPEG1-Layer2, MP3 audio decode

• 

Line 21 Closed Caption EIA 608 pass through

• 

Supports AFD or Manual aspect ratio configuration, 4:3 or 16:9

Before You Begin

Unpacking the Unit

You will find the following items in the box: 

•  

Clearview NTSC16

 Decoder (QTY=1)

• 

 Power Cord with IEC C13 line socket and 3-pin Type B NEMA 5 plug (QTY=1)

The 

Clearview NTSC16

 is designed to be installed in a standard 19-inch (483 mm) rack (EIA 310-D, IEC 60297, and DIN 41494 

SC48D).

To install, secure the unit's front panel to the rack by inserting four (4) machine screws, with cup washers, through the 

four (4) mounting holes in the front panel. A 1RU open space is recommended above the unit for ventilation.

Step 1: Setup and Install of the Unit

To power the unit up, connect the IEC line cord to the receptacle on the rear panel. Then connect the other end to a 

120 VAC power outlet.  The input power receptacle is equipped with a fuse-holder and fuse (SLO-BLO, 3.0 Amp, 250V).

DO NOT BLOCK THE UNIT'S AIR INTAKE OR AIR DISCHARGE OPENINGS

The Unit performance will be degrated without proper ventilation.

Excessive heat will shorten the life of the unit.

WARNING

For safe and reliable operation, the ground pin of the power cord must be grounded properly.

1

2

Summary of Contents for Clearview NTSC16

Page 1: ...bject to change without notice All trademarks are property of their respective owners Clearview NTSC16 Quick Guide Stock Model Name Description 6566 Clearview NTSC16 IP Digital to RF Analog Synthesizer 16 Channels IP Digital to RF Analog Synthesizer MPEG 2 H 264 AVC H 265 HEVC for up to 16 NTSC Modulated Channels ...

Page 2: ...4 3 or 16 9 Before You Begin Unpacking the Unit You will find the following items in the box Clearview NTSC16 Decoder QTY 1 Power Cord with IEC C13 line socket and 3 pin Type B NEMA 5 plug QTY 1 The Clearview NTSC16 is designed to be installed in a standard 19 inch 483 mm rack EIA 310 D IEC 60297 and DIN 41494 SC48D To install secure the unit s front panel to the rack by inserting four 4 machine s...

Page 3: ...be found using the search box in the Start Menu or for Windows 8 x the Start Screen b Once open click on Change Adapter Settings on left hand side of the window c Right click on the Local Area Connection and then click on the Properties d A dialog box entitled Local Area Connection Properties will appear In this box double click on the Internet Protocol Version 4 TCP IPv4 e A dialog box entitled I...

Page 4: ...b located on the right side of the navigation menu at the top Step 4 Basic Configuration System Status Once you are logged into the unit you will be presented with the System Status page Status tab Status Page Full View Step 3 Login to the Controller An Ethernet Cable should be connected between your PC and the Control port on the unit Open a Web browser Chrome or Firefox recommended and type http...

Page 5: ...er can choose to set the unit back to the default factory settings with a click of a button System Settings Go to the System tab to change the System Settings including unit identification and network settings System Page Full View The following Ethernet Settings can be changed IP address Subnet Mask Default Gateway and the Primary and Secondary DNS In addition the network settings for each decode...

Page 6: ...the left side is interactive Clicking on a decode block displays the corresponding settings in the Video Audio Pipeline Settings table located on the right side The corresponding tab is also highlighted for persistent indication of the Decode pipeline settings currently being shown Step 5 Decoder Configuration Decoders Settings The final information to setup within the unit is located in the Decod...

Page 7: ...255 0 0 3 The Management PC is configured to be at 192 168 3 5 with a subnet mask of 255 255 0 0 Note The subnet mask of the Video Source device must be configured to be on the same subnet mask as the Management PC Accessing devices from the Management PC To access the Video Source device go to http 192 168 3 18 To access the Clearview NTSC unit go to DC1 1 at http 192 168 6 71 Note Additional Cle...

Page 8: ...23 6049 Ext 4256 or visit our website www blondertongue com for further information Product and Documentation Updates Download the latest User Manual PDF by visiting our website Navigate to the product page by entering the full Model Name or Stock Number in the search field Upon reaching the product page the User Manual download link will be located beneath the product image Firmware Updates are a...

Reviews: