Summary of Contents for NB-R1260E

Page 1: ...tructions Functions Operation 2 8 5 7 This product was manufactured for household use only Read all operating instructions before installation and use Please save this operating instruction manual and place it in an easily accessible location External appearance and specifications are subject to change for the improvement of a product without notice NB R1260E NB R1260R Personal Hygiene Appliance ...

Page 2: ...ice representative Do not dismantle repair or alter the unit Do not pour or spray water on to the unit The unit must be grounded Do not touch the power plug with wet hands Properly connect the power cord to the electrical outlet corresponding to the rated voltage of the unit Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged ...

Page 3: ... service center Caution against low temperature burns Before removing the unit from the toilet bowl disconnect the power plug first Do not connect other electrical appliances to the same power socket connected to the unit CONSERVEZ CES INSTRUCTIONS SAVE THESE INSTRUCTIONS Ne raccordez pas l alimentation principale en eau à la conduite d eau chaude raccordez la uniquement à la conduite d eau froide ...

Page 4: ...roduct is for use on a nominal 120 V circuit and has a grounding plug that looks like the plug illustrated in Figure A A temporary adapter which looks like the adapter illustrated in Figure B and C may be used to connect this plug to a 2 pole receptacle as shown in Figure B if a properly grounded outlet is not available The temporary adapter should be used only until a properly grounded outlet Fig...

Page 5: ... Main Unit Cleansing Nozzle Seat Sensor Outlet of warm air dryer Bidet Nozzle Seat Control Panel Water Inlet Lid Power Plug Night Light Lamp Parts Identification 5 Remote control receiver ...

Page 6: ...Hose for Main Unit Fastening Bolts Rubber Grommets Washers Fastening Nuts Remote control Mounting plate Batteries 6 Control Panel Remote control Unit control panel Brackets For the installation on toilets with top tighten the bolt Refer to installation ...

Page 7: ...eeps if the cleansing or bidet function is over Move cleansing runs by pressing CLEANSING or BIDET button while using When using the unit please sit in the center The seat sensor is installed on the inside of the seat part The unit begins to operate only when a user s skin touches the seat sensor In case of a seat cover or something on the seat the seat sensor may not operate because the seat sens...

Page 8: ...en A buzzer will sound when the auto cleansing function is finished Default settings for this function are Level 3 for water pressure Level 2 for warm air drying temperature and Level 3 for the nozzle position These settings may be adjusted to suit user preference When activated the auto cleansing function will revert settings for both water and seat temperature to Medium by default Setting may be ...

Page 9: ...s shut off No need to readjust the temperature settings after a power failure 9 Nozzle Position Adjustment Press the or button to adjust the nozzle position during the CLEANSING or BIDET function The unit remembers the last nozzle position settings Water Pressure Adjustment The unit remembers the last water pressure settings Water pressure can be adjusted by pressing the or button Levels 1 5 When t...

Page 10: ... in spite of an electrical outage so no need to reset functions after power is back In SMART Eco Mode Eco mode programs analyze user s time zones of use and control the temperature of heated seat and water as follows The seat temperature is maintained at 86 30 in analyzed time zones of use The seat temperature is maintained at 77 25 in analyzed time zones of not using Water temperature is maintain...

Page 11: ...peration the self nozzle cleaning function runs and sanitizes the nozzle head SMART Nozzle Cleaning When SMART Eco mode is activated the Eco mode programs analyze user s time zones of use and operate Nozzle Cleaning function for 4 times automatically during not using Possible to stop the operation of SMART Nozzle Cleaning if pressing STOP button or sitting on the seat Nozzle Cleaning Press the NOZ...

Page 12: ...nection should be done by authorized service personnel only Do not connect the power until installation is finalized Check all the accessory parts are in place Remove the existing toilet seat Remove the existing toilet seat and lid by unfastening fastening nuts underneath Keep the detached seat lid and nuts for later use Drain toilet water tank completely after turning off the water supply by turnin...

Page 13: ...le spacing is required for a typical installation If your bolt hole spacing is different a custom solution is needed to affix catch plate bracket to the toilet Contact us for additional details Install Mounting Plate for Standard Installation Fasten the catch plate with fastening bolts after setting in place the brackets on the catch plate 4 B This method will use a combination of the included Bracke...

Page 14: ...er the bidet unit 6 Connect the flexible hose to the bidet 5 T valve The bidet seat should slide all the way back and lock into the mounting bracket It should not be able to slide forward once locked If you choose to install a water filter install it between the t valve and supply hose 14 Water inlet Flexible hose ...

Page 15: ...d insert remote control back into the remote control mounting plate Use only AA LR6 1 5V batteries There is a risk of explosion if battery is replaced with the wrong type Dispose of used batteries properly according to battery manufacturers instructions Insert the batteries according to the indications marked on the remote control Do not use the used battery and new one together Double sided tape ...

Page 16: ...rol To test the water spray operation press the CLEANSING STOP button while placing your hand on the seat sensor Do not invert or otherwise move the bidet while it is connected to power and water Doing so may cause damage to the unit Get ready to cover the nozzle with your other hand to prevent water spraying out of the bowl WARNING 1 2 3 5 Shut off valve To fill the water reservoir press the CLEANS...

Page 17: ...ate and unfasten the catch plate from the toilet Unfasten the drain plug underneath the unit and drain the water completely in the water tank Disconnect the PVC flexible hose and T valve Connect the water supply hose to the shut off valve Open the shut off valve by turning counterclockwise and check any leakages on the connections Reinstall the original seat and lid to the toilet 1 2 3 4 5 6 7 8 To d...

Page 18: ...ccasion detach the body of a unit from the toilet bowl first and detach the hose from the water inlet 1 2 Begin by detaching the strainer from the water inlet clean and insert it again In case that it is hard to detach the strainer with a hand try again with a kind of nippers After attaching the hose to the water inlet turn the water supply valve to the left and have it opened 3 4 Cleaning the Wate...

Page 19: ...e water into the plug or socket Touching the power socket with wet hands can cause an electric shock Press the NOZZLE CLEANING button The nozzle moves for 2 minutes back and forth the wash water comes out and the nozzle is cleaned Press the NOZZLE CLEANING button for more than 3 seconds The nozzle comes out and stops Clean the nozzle manually with a soft brush Press the STOP button and the nozzle ...

Page 20: ...he drain hose unfasten the drain plug and drain the water tank completely 3 Connect the power plug and check if the unit power is on Do not turn off the WATER TEMP level and adjust water temperature to Low or higher 1 2 If not in use for a long time drain the water tank 3 Freeze Prevention during Winter 20 Drain plug Low Medium High ...

Page 21: ...n be used for about 40 seconds at the Medium setting of water pressure It will take about 3minute to regain the selected temperature Have you checked if a seat cover or something had been on the surface of the seat The unit begins to operate only when a user s skin touches the seat sensor The warm seat temperature level is turned off or set to Low Dryer air is not warm The warm air dryer temperatur...

Page 22: ...40 389mm x 530mm x 155mm 4 2kg 389mm x 495mm x 155mm 4 1kg NB R1260E NB R1260R Max Power Consumption Length of Power Cord Water Supply Connection Water Supply Pressure Cleansing Water Flow Rate Cleansing Warm Seat Bidet Water Pressure Adjustment Temp Adjustment Heater Capacity Safety Device Temp Adjustment Heater Capacity Safety Device Water Supply Temp Temp of circumstance for use Product size Pr...

Page 23: ...ion 2 Defect or damage occurring from fire gas flood earthquake lightning other natural calamities pollution or abnormal electrical power 3 Defect or damage occurring from outside of normal household usage long term public usage used inside a vehicle installed inside a vessel etc 4 Defect or damage occurring from the transportation of mistreatment after purchase 5 Defect or damage occurring during r...

Page 24: ...NCM CO LTD 119 86 SASA DONG SANGNOK GU ANSAN SI GYEONGGI DO KOREA www bloomingbidet co kr TEL 82 31 419 4070 FAX 82 31 419 4072 Made in Korea 6522 0529 00 Rev 0 ...