background image

340001-026 3/16

  

CJW Series

Convertible Well Jet Pump Water Systems 

OPERATING INSTRUCTIONS & PARTS MANUAL

For parts, product & service information visit

 www.blueangelpumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2016, Blue Angel Pumps, Harrison, Ohio.

DESCRIPTION

Jet pumps are single stage domestic water pumps designed for pumping 
potable water in applications where the water is up to 100 feet below 
pump center line. A pressure switch is a standard feature. A built-in control 
valve is available on deep well pumps. Deep well pumps can be mounted 
to either a pre-charged, conventional type, or free standing pressure tank.

UNPACKING

After unpacking the jet pump, carefully inspect for any damage that may 
have occurred during transit. Check for loose, missing or damaged parts.

SAFETY GUIDELINES

To help recognize this information, observe the following signal words/
hazard classifications.

 

Danger indicates an imminently hazardous 

  situation which, if not avoided, WILL result in 

death or serious injury.
 

Warning indicates a potentially hazardous 

  situation which, if not avoided, COULD result in 

death or serious injury.
 

Caution indicates a potentially hazardous 

  situation which, if not avoided, MAY result in 

minor or moderate injury.
 

Notice indicates important information, that if 

  not followed, may cause damage to equipment.

This is the safety alert symbol. It is used to alert you to potential 

bodily injury hazards. Obey all safety messages that follow this 

symbol to avoid possible harm.

NOTE: Information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

 

This product or its power cord contains 

  chemicals, including lead, known to the State of 

California to cause cancer and birth defects or other reproductive harm. 

Wear gloves when handling this product, and wash hands after handling.

GENERAL SAFETY

1.  Read all manuals included with this product carefully. Be 

thoroughly familiar with the controls and the proper use 
of the equipment. 

2.  Know the pump application, limitations and potential 

hazards.

 

Always install a pressure relief valve to 

  match the system pressure rating and the 

maximum flow rate.

 

Do not use to pump flammable or 

  explosive fluids such as gasoline, 

fuel oil, kerosene, etc. Do not use in explosive atmospheres. 

Pump should be used to pump ONLY clear water. Failure to 

follow this warning will result in death or serious injury.
 

Disconnect power and release all pressure from 

  the system before attempting to install, service, 

relocate or perform any maintenance. Lock the power disconnect in the 

open (off) position. Tag the power disconnect to prevent unexpected 

application of power.
 

Install a screen around the inlet pipe to prevent 

  entrapment of swimmers.

3.  Drain all water from the system before servicing.
4.  Periodically inspect pump and system components. Perform routine 

maintenance as required (See Maintenance, page 8).

5.  Personal Safety: 

a.  Wear safety glasses at all times when working with pumps.
b.  Keep work area clean, uncluttered and properly lighted replace 

all unused tools and equipment.

c.  Keep visitors at a safe distance from work area.
d.  Make the workshop child proof: use padlocks, master switches 

and remove starter keys.

6.  Do not pump chemicals or corrosive liquids. Pumping these liquids 

shortens the life of the pumps seals and moving parts and will void 
the warranty. Pump ONLY clear water.

7.  When installing pump, cover the well to prevent foreign matter from 

falling into well and contaminating the water and damaging internal 
mechanical pumping components.

8.   Always test the water from the well for purity before use. Check with 

local health department for test procedure.

9.   Complete pump and piping system MUST be protected against 

below freezing temperatures. Freezing temperatures could cause 
severe damage and void the warranty.

10.  Do not run the pump dry or damage will occur and will void 

warranty.

 

This pump is designed for indoor 

  installation only. Failure to install 

indoors will significantly increase the risk of injury or death 

from electrical shock.
 

All wiring should be performed by a licensed 

  or certified electrician.

11. For maximum safety, the unit should be connected to a grounded 

circuit equipped with a ground fault interrupter device (GFCI).

12.  Before installing the pump, have the electrical outlet checked by a 

licensed or certified electrician to make sure the outlet is properly 
grounded.

Read and save these instructions. This manual contains very important Safety Warnings and Operating Instructions. You will need to refer to it before attempting any installation or maintenance. Always 
keep this manual with the unit so that it will be easily accessible. Failure to read and follow these warnings and instructions could result in property damage, serious injury or death.

Scan QR, or Log on to waynepumps.com and search your model number, to download a multilingual version of this manual

Escanee el código QR o visite waynepumps.com y busque su número de modelo para descargar una versión multilingüe de este manual

Summary of Contents for 100CJW

Page 1: ...ious injury Disconnect power and release all pressure from the system before attempting to install service relocate or perform any maintenance Lock the power disconnect in the open off position Tag th...

Page 2: ...is to store a quantity of water under pressure When full the tank contains approximately 2 3 water and 1 3 compressed air The compressed air forces the water out of the tank when a faucet is opened An...

Page 3: ...5 feet vertically of the water level See converting to shallow well pump on page 6 Shallow well installations have only one pipe between the pump and water supply Figure 2 DRILLED WELL FIGURE 16 1 Ins...

Page 4: ...E AND SPRING WITH TWO PIPE JET FIGURE 16 ON PAGE 10 1 Install a 1 1 4 in foot valve not included to the jet body A 1 1 4 in coupling is required to connect the larger pipe to the jet assembly 2 Connec...

Page 5: ...TANK FIGURE 7 1 Check tank pre charge using a tire pressure gauge Set air pressure in tank to 28 psi which is 2 psi below pressure switch cut in level An air valve is located on the side and will acc...

Page 6: ...re used run a wire directly to the metal well casing or use a ground electrode furnished by the power company There is only one proper ground terminal on the unit The terminal is located under the pre...

Page 7: ...INTENANCE Disconnect power and release all pressure from the system before attempting to install service relocate or perform any maintenance Lock the power disconnect in the open off position Tag the...

Page 8: ...y attention to how the original shaft seal is installed before disassembly 10 Remove the shaft seal from the impeller make sure the stainless steel sleeve comes off the impeller all you should see on...

Page 9: ...plastic cap over the motor shaft end 21 Reassemble the diffuser make sure the arrow indicating the top is pointed toward the top of the pump torque the two screws to 30 10 inch pounds 22 Using the 4 c...

Page 10: ...in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILLED WELL A hole bored into...

Page 11: ...ace as necessary 6 Clogged nozzle deep well 6 Pull jet and clear obstruction 7 Air volume control diaphragm ruptured 7 Replace air volume control See Page 6 8 Foot valve may be clogged or stuck closed...

Page 12: ...f any Part description and number as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A 13 REPLACEMENT PARTS LIST Ref No Part Number f...

Page 13: ...528 384 588 444 330 264 234 Jet Diameter Pump Model No Jet Assembly No Vertical Distance to Pumping Level 30 40 50 60 70 80 90 100 Output in Gallons Per Hour GPH 2 in 50CJW 50CJW 56319 55462 620 590...

Page 14: ...14 Operating Instructions and Parts Manual NOTES www blueangelpumps com...

Page 15: ...15 NOTES www blueangelpumps com CJW Series...

Page 16: ...HATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i...

Page 17: ...al manipular este producto y l vese las manos despu s de manipularlo SEGURIDAD GENERAL 1 Lea con atenci n el manual de instrucciones incluido con este producto Familiar cese bien con los controles y...

Page 18: ...PRE INSTALACI N FUENTES DE SUMINISTRO DE AGUA Las posibles fuentes de suministro de agua se ilustran en la Figurra 16 en la p gina 27 Se pueden clasificar en dos categor as AGUAS DE SUPERFICIE Agua de...

Page 19: ...ndo se necesite dar servicio o almacenarlas Una manguera de caucho instalada entre el sistema de agua y la tuber a de la casa reducir el ruido que se transmite a la casa Se pueden usar tuber as de pl...

Page 20: ...siempre sumergida Figura 3 Eyeccion de Chorro por Dos Tubos CUERPO DEL EYECTOR DE CHORRO V LVULA DE ASPIRACI N TUBER A DE 3 2 CM 2 54 CM 1 PULG PIPE TUBER A DE 3 2 CM Figura 4 Chorro de 1 Tubo TAMP N...

Page 21: ...ecci n del tubo y baje el eyector de chorro dentro del pozo 4 Agregue tuber a hasta que el eyector de chorro est entre 1 52 y 4 57 m 5 y 15 pies por debajo del nivel de agua m s bajo que se anticipa N...

Page 22: ...ores Seleccione los alambres y el fusible del tama o adecuado Tabla 2 Para la protecci n del circuito del motor se recomiendan los fusibles que interrumpen por un tiempo en vez de los fusibles convenc...

Page 23: ...el motor y vuelva a llenar la bomba con agua El tiempo necesario para cebar es proporcional a la cantidad de agua en la tuber a de ingreso No permita que la bomba se caliente 6 Deje que el sistema fun...

Page 24: ...conectar la corriente el ctrica a la bomba NOTA Conforme la bomba vuelve a llenar el tanque con agua el control de volumen de aire suministra al tanque la relaci n adecuada de aire y agua para que el...

Page 25: ...mpulsor sobre el eje del motor apriete a mano Lubrique la nariz del impulsor con lubricante seguro para agua potable 20 Vuelva a colocar la tapa de pl stico sobre el extremo del eje del motor 21 Vuelv...

Page 26: ...Sp 26 Manual de instrucciones de funcionamiento y piezas de repuesto NOTAS www blueangelpumps com...

Page 27: ...rra por debajo de la capa fre tica La profundidad por lo general es menor a 15 25 m 50 pies Los di metros comunes fluct an entre 2 5 cm 1 y 5 1 cm 2 E POZO PERFORADO Un hoyo perforado en la tierra con...

Page 28: ...a de la bomba 1 Baje m s el tubo de succi n dentro del pozo 2 La v lvula de control est demasiado abierta pozos profundos 2 Ajuste la v lvula de control o repita el procedimiento de cebado 3 Al cebar...

Page 29: ...nectado a la salida incorrecta de la bomba 3 Mueva a la apertura correcta de la bomba 4 Precarga de tanqueincorrecta Tanque precargado 4 Agregue o quite aire cuanto sea necesario 5 Diafragma o bolsa r...

Page 30: ...respondencia a N mero del modelo BLue Angel Pumps C digo impreso 101 Production Drive Descripci n y n mero del repuesto seg n la lista de repuestos Harrison OH 45030 U S A LISTA DE PARTES DE REPARACI...

Page 31: ...2673 2018 1500 1200 1064 Di metro del Charro Modelo de Bomba No Ensamblado del Chorro No Distancia Vertical al Nivel de Bombeo En Metres 9 1 12 2 15 2 18 3 21 4 24 4 27 4 30 5 Entrega en Litros por Ho...

Page 32: ...EXCLUS Certaines Provinces n autorisent pas de limites de dur e pour les garanties implicites ni l exclusion ni la limite des dommages fortuits ou indirects Les limites pr c dentes peuvent donc ne pa...

Reviews: