background image

    

     

 

    

     

 

    

     

 

Blue Coat recommends that you connect the appliance and verify the LEDs and LCD display to 
ensure functionality before rack mounting the appliance.  

If you want to install the appliance into a rack before performing any configuration tasks, begin with 

Rack Mount the Appliance

.  

 

Note

: Network cables are not included and must be supplied by the user.  

 
Figure 1 shows a typical Blue Coat ASG-S200 network deployment: 
 
 
 
 
 
 
 
 
 
 
 

 

The following installation assumes the network deployment shown in Figure 1 is in use. For more  
information, see the product guides

 

at: 

https://bto.bluecoat.com/products/advanced-secure-gateway

 

 

 

 

To deploy your ASG-S200 appliance 

(Figure 2)

:

 

1. 

Remove the EULA (End User License Agreement) sticker located 
on the rear of the appliance. Be aware that you are agreeing to 
the terms and conditions of the EULA by removing the sticker and 
installing the product. 

 

2. 

Disconnect the existing LAN switch cable from the WAN router.

 

3. 

Connect the Ethernet cable from the LAN switch and plug it into the 

2:1 

port network interface on 

the ASG-S200 appliance.

 

4. 

Connect an Ethernet cable from the WAN router to the 

2:0 

port network interface on the ASG-

S200 appliance. The interface auto-negotiates 10/100/1000 Base-T speed and duplex settings.

 

5. 

Connect a network cable between the 

SYS MGMT 0:0 

port network interface and the router (or 

switch) leading to the management network.

 

6. 

Connect a null-modem serial cable from the ASG-S200 appliance to a PC (or serial terminal). 
This connection is used to perform initial configuration via a direct serial connection. 

 

7. 

Connect the socket end of the enclosed power cord into the power supply inlet, and then connect 
the plug into a power source.

 

If the appliance does not automatically power on, switch the 

appliance on by pressing the rear soft power switch and continue to          .

 

 

Note: 

This appliance retains memory of being turned off with the soft power switch. In such cases, 

the soft power switch must be used to turn it back on after power is connected. However, if power is 
disconnected while the appliance is on, it will automatically turn on when power is restored. 

 

 

 

3

 

 

Connect the Cables 

 

 

2

 

 
Unpack the shipment package and verify the contents of the box.  
 
The Blue Coat ASG-S200 series appliance ships with the following components: 

 

Blue Coat ASG-S200 series appliance 

 

Software License Agreement 

 

 

One AC power cord 

 

Safety and Regulatory Compliance Guide 

 

 

Null-modem serial cable 

 

Quick Start Guide 

(this document) 

 

Fixed mount brackets w/ installation hardware 

 

Rack mount ears (for use with optional slide-
rail kit) 

3

 

Unpack the Appliance  

 

1

 

Quick Start Guide 

Advanced Secure Gateway: ASG-S200 Series

 

    

    

 

 

 

Flip over to complete the installation 

3

 

Perform Initial Configuration  

 

4

 

 
You must have the following network information on hand to perform initial configuration:  

To access the ASG-S200 command-line interface and run the initial configuration wizard:

 

1. 

Confirm that a null-modem serial cable is connected from the ASG-S200 appliance to your 
workstation serial port. For cabling instructions, see           

Connect the Cables

.

 

2. 

Open a terminal emulation program such as Microsoft HyperTerminal

®

, PuTTY, Tera Term, or 

Procomm

.

 

3. 

Configure the terminal emulation software to the following settings: 

 
 
 

 

4. 

Power on the ASG-S200 appliance. After the appliance boots up, you will be prompted to press 

<

Enter

three times to start the initial configuration wizard.

 

5. 

Press 

<

Enter

three times. The configuration process begins.

 

6. 

Choose a configuration method:

 

 

[

Manual Setup

] Select this method if you are configuring the ASG-S200 appliance without 

Director (provides centralized management for ASG appliances).

 

 

[

Director-managed setup

] Select this method if you are registering this ASG-S200 with 

Director. You will need the Director appliance IP address and registration password. 

 

7. 

Enter the network configuration parameters when prompted. If your ASG-S200 appliance is 
connected to the network, the configuration wizard will attempt to verify DNS server addresses 
and auto-detect link settings.

 

Baud rate: 

9600 bps

 

Data bits: 

8

 

Flow control: 

none

 

Parity: 

none

 

Stop bits: 

1

 

 

 

ASG-S200 IP address 

 

Default Gateway IP address 

 

Subnet mask 

 

Primary DNS server IP address 

 

Console password to access advanced 
commands in the CLI 

 

Admin password for authorizing access to the 
appliance 

 

Verify the LEDs and LCD Display  

 

3

 

 

 
 
 
To verify that the appliance has booted and is operational, check the following: 

 
Figure 3 shows the location of all the major control functions located on the front panel of the ASG-
S200 series appliance. After the appliance boots up, the 

System Management LED 

should be 

Off 

while the 

Power LED 

should alternate between 

amber 

and 

green

, denoting an unconfigured state.  

Note: 

Following the initial configuration, the System Management LED continues blinking amber until 

a valid license is applied to the appliance. 

 

 
After the appliance has been configured for network access, the LCD displays various system 
statistics. You can use the left and right arrows to manually scroll through the statistics modes. 
 

 

6

 

 

3

 

 

2

 

 

4

 

For additional installation details and configuration options, see the 

 

Advanced Secure Gateway 

documentation available at: 

https://bto.bluecoat.com/products/advanced-secure-gateway

 

 

 

After your ASG-S200 appliance is configured for network access, complete the installation by verifying 
network connectivity and licensing the appliance. The ASG-S200 relies on a 

base license

, consisting of 

the primary operating components of the Proxy and Content Analysis features, and 

add-on licenses 

which includes optional elements, such as file inspection subscriptions and specialized Proxy features. 
 
Licensing the ASG is a multi-step process. You must first install the base license, activate and install the 

Proxy licenses, and then activate and install the file inspection subscriptions. Keep in mind, you’ll need 

Internet connectivity to access the Blue Coat Licensing Portal (BCLP) to activate your optional add-ons.  
 
To complete the ASG-S200 installation:  

1. 

Verify that you can log in to the appliance via the Web browser. To log in to the appliance: 

 

a. 

Enter the ASG-S200 IP address into your Web browser's 

Address 

or 

Location 

box using 

the following format: 

https://A

SG_ipaddress

:8082

 

b. 

Enter the user name and password specified during configuration to access the 
management console. The management console loads within your browser window.

 

2. 

Activate the base license from the management console: 

 

a. 

Navigate to the License page: 

Proxy > Maintenance > Licensing > Install  

b. 

Click 

Retrieve

. The appliance automatically contacts the Blue Coat licensing server and 

installs the base license.

 

3. 

Activate optional Proxy licenses and/or file inspection subscriptions, if any were purchased:

 

a. 

Visit the Blue Coat Licensing Portal at: 

https://services.bluecoat.com 

and log in using your 

BlueTouch Online credentials.

 

b. 

Enter an activation code provided in your e-fulfilment letter and click 

Next

.

 

c. 

Enter your appliance serial number, click

 Next

 and follow any on screen prompts to 

complete the activation.

 

d. 

Repeat 3b 

 3c for each optional license and subscription you wish to activate.

 

4. 

Download and install the updated license:

 

a. 

Navigate to the License page: 

Proxy > Maintenance > Licensing > Install  

b. 

Click 

Retrieve

. The appliance automatically contacts the Blue Coat licensing server and 

installs the updated license.

 

5.  To validate that all services are available, 

you must restart your appliance

a. 

Navigate to 

Proxy > Maintenance > Tasks

.

 

b. 

Select the 

Hardware and software 

radio button.

 

c. 

Click 

Restart now. 

Note

: The appliance can take up to 10 minutes to restart. 

DO NOT unplug the power 

cables during the restart process as this can cause a corruption of the configuration.

 

6. 

Enable file inspection subscriptions, if any were purchased:

 

a. 

Navigate to the Content Analysis License page: 

Content Analysis > System > Licensing

Each licensable service shows the following details:

 

 

Status

: The availability of a service component and the expiration date. 

 

Active

: The activation status of the component. 

b. 

Select a service component checkbox to activate it.

 

c. 

Click 

Save Changes

.

 

7. 

To prepare the ASG-S200 for rack mounting, gracefully shutdown the appliance using the 

shutdown 

command.

 

a. 

Access the ASG-S200 command-line interface (see          for more information).

 

b. 

When prompted, press 

1

 to access the CLI. 

 

c. 

Enter 

enable 

to access privileged commands.

 

d. 

Enter 

shutdown 

to turn off the appliance.

 

 

Important! Do not shut down the appliance using the switch or by removing the power cables! 
Abruptly removing power can result in irreparable data loss. 

Always 

use the shutdown command 

from the CLI to power down the appliance 

3

 

License the ASG-S200 Appliance 

 

5

 