ProxySG 900 Series Maintenance & Upgrade Guide
29
Fan Assembly
This section describes how to replace a fan assembly in the ProxySG 900 Series appliance.
The ProxySG 900 Series appliance contains seven identical serviceable fan assemblies that
maintain the ideal temperature for the system components - two power supply fan units (one
for each PSU inlet) and five system fan units.
Note:
The fan assemblies are hot-swappable; you can remove and replace a faulty fan
assembly while the appliance remains powered on.
The fan assemblies are numbered from left to right as indicated in the diagram. Each fan
assembly consists of two counter-rotating fan units.
Pre-Installation Checklist
Item
Description
Tools Required
None
Components Supplied
Fan assembly
Other Required Components
None
Safety Notices
●
See “Safety Warnings and Cautions” on page 8.
●
Put on an electrostatic discharge (ESD) strap before opening the appliance.