Safety characteristics
The AIRSKIN® Safetyflange has been certified and EC type-examined by TÜV AUSTRIA in accordance with EN ISO
13849 in Performance Level e, Category 3 and EN/IEC 62061 in SIL3 as a safety component.
14.1 PFH
D
The PFH
D
(probability of dangerous failure per hour) value / MTTF
D
(mean time to dangerous failure) value for the
AIRSKIN® Safetyflange can be derived from the following table.
PFH
D
1
MTTF
D
2
DC
3
2
.
5
×
10
−
8
2007
.
57
99
%
14.2 B10
D
The stated PFH
D
value is calculated by assuming that the AIRSKIN® Safetyflange is actuated once per shift in 3-
shift operation. Please contact Blue Danube Robotics if you want to calculate the PFH
D
value with other demand
rates.
1
Probability of dangerous failure per hour
2
Mean time to dangerous failure
3
Diagnostic coverage