Step 11

After the burner and the emitter are clean, reassemble the burner to the main supply tube.  Be careful to insert the 
thermal-couple and igniter into the hole in the heat shield.  Before reattaching the emitter to the emitter bottom, 
insert a propane tank into the valve housing and check to ensure that the heater lights. 

Make sure the burner sits straight.  

Note: 

 The burner top cannot be tipped to one side or the other. If the burner is not straight; the emitter will not be 

heated evenly.  This will cause the heater to perform improperly.   Once the burner is installed correctly, replace 
emitter and dome.

Summary of Contents for Endless Summer 60000 Series

Page 1: ...Cleaning emitter and burner Series 60000 66000 70000 91000 LP Gas ...

Page 2: ...gloves 1 Installation and repair should be done by a qualified service person 2 Use only Blue Rhino Global Sourcing LLC factory authorized parts The use of any part that is not factory authorized can be dangerous This will also void your warranty Contact 1 800 762 1142 3 Do not use flammable solutions or material to clean heater or heater parts Use only warm soapy water to clean outside of heater ...

Page 3: ...Cleaning emitter and burner Series 6000 93000 LP Gas 405121 3 For assistance call 1 800 762 1142 Steps 1 3 1 Remove propane cylinder 2 Remove dome 3 Remove wire guard ...

Page 4: ...Cleaning emitter and burner Series 6000 93000 LP Gas 405121 4 For assistance call 1 800 762 1142 Step 4 Using a 2 Phillips screwdriver remove the 4 screws that secures the emitter to the emitter bottom ...

Page 5: ...000 93000 LP Gas 405121 5 For assistance call 1 800 762 1142 Step 5 1 Using a non abrasive scouring pad clean the outside and inside of the emitter 2 Finish up by blowing any loose soot off the emitter with air or a can of compressed air ...

Page 6: ...Cleaning emitter and burner Series 6000 93000 LP Gas 405121 6 For assistance call 1 800 762 1142 Step 6 To remove the burner from the emitter bottom unscrew the 2 screws ...

Page 7: ...nce call 1 800 762 1142 Step 7 1 In the post locate the 4 oblong holes In two of the holes there are 2 small screws Note The 2 screws are opposite of each other 2 Remove both of these screws Use care not to lose them Once the screws have been removed carefully remove burner ...

Page 8: ...s 6000 93000 LP Gas 405121 8 For assistance call 1 800 762 1142 Step 8 With the burner removed clean the inside of the venturi tube Insert a bottle brush completely into the venturi tube and twist a couple of times to loosen any debris ...

Page 9: ...es 6000 93000 LP Gas 405121 9 For assistance call 1 800 762 1142 Step 9 Use a pipe cleaner to clean all burner ports Clean the top of the heat shield on the burner with a non abrasive scouring pad to remove any soot or carbon build up ...

Page 10: ...rner Series 6000 93000 LP Gas 405121 10 For assistance call 1 800 762 1142 Step 10 With the venturi tube burner ports and the heat shield cleaned use the air or a can of compressed air to blow out any soot or carbon build up ...

Page 11: ...nto the hole in the heat shield Before reattaching the emitter to the emitter bottom insert a propane tank into the valve housing and check to ensure that the heater lights Make sure the burner sits straight Note The burner top cannot be tipped to one side or the other If the burner is not straight the emitter will not be heated evenly This will cause the heater to perform improperly Once the burn...

Page 12: ...ollow all leak checking procedures before operating To prevent fire or explosion hazard when testing for a leak a Always perform leak test before lighting the heater and each time the tank is connected for use b No smoking Do not use or permit sources of ignition in the area while conducting a leak test c Conduct the leak test outdoors in a well ventilated area d Do not use matches lighters or a f...

Page 13: ...serious bodily injury or damage to property 3 Please refer to diagram for proper installation 4 If the burner pipe does not rest flush to the orifice please contact 1 800 762 1142 for assistance Tank Gas Line Connection 1 Make 2 3 oz of leak solution by mixing one part liquid dishwashing soap with three parts water 2 Make sure control knobs are off 3 Turn LP gas tank ON at valve 4 Spoon leak check...

Page 14: ... USA 1 800 762 1142 www bluerhino com 2004 Blue Rhino Global Sourcing LLC All Rights Reserved Endless Summer is a registered trademark of Blue Rhino Global Sourcing LLC All Rights Reserved Blue Rhino is a registered trademark of Ferrellgas L P All Rights Reserved 60009300CI IS 102 ...