Outdoor Patio Heater Model No. 62900 & GWT501A
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
Insert and Secure (1) 14.1 oz or (1) 16.4 oz LP Gas Tank
Only cylinders marked “propane” may be used.
Note
: Some 1-lb cylinders may form frost when near empty.
Line up threads on canister with those on regulator, insert
and rotate canister clockwise until they fit snugly together.
HAND TIGHTEN ONLY. Be careful not to cross threads when
screwing in canister.
Disconnect (1) 14.1 oz or (1) 16.4 oz LP Gas Tank
Before disconnecting make sure the heater control valve is
“OFF”.
Rotate LP gas tank counterclockwise until it is loose.
Store the LP gas tank in a proper location.
Need a tank of gas?
Try tank exchange service. It’s easy, fast, safe,
and available at tens of thousands of conveniently located retail outlets
nationwide. You can purchase a new full tank or exchange your empty
for a precision filled one.
OFF
ON
HIGH
LOW
OFF
ON
HIGH
LOW
Operating Instructions
Inspect the visible portion of the hose before each use of the appliance. Inspect the entire hose
assembly at least annually.
Checking for Leaks
Burner Connections
Make sure the regulator valve and hose connections are securely
fastened to the burner and the tank.
If your unit was assembled for you, visually check the connection
between the burner pipe and orifice. Make sure the burner pipe fits
over the orifice.
WARNING: Failure to inspect this connection or
follow these instructions could cause a fire or an
explosion which can cause death, serious
bodily injury, or damage to property.
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice,
please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
Make 2-3 oz. of leak solution by mixing one part liquid
dishwashing soap with three parts water.
Make sure control knobs are off.
Turn LP gas tank ON at valve.
Spoon leak check solution at all “x” and arrow locations.
If any bubbles appear turn LP gas tank “OFF”, reconnect and re-test. If you continue to see
bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for
assistance.
If no bubbles appear after one minute turn tank “OFF”, wipe away solution and proceed.
Before Turning Gas Supply ON
Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a
building, garage, or any other enclosed area.
Make sure surrounding areas are free of combustible materials, gasoline, and other flammable
vapors or liquids.
Ensure that there is no obstruction to air ventilation.
Be sure all gas connections are tight and there are no leaks.
Be sure the access panel is clear of debris.
Be sure any component removed during assembly or servicing is replaced and fastened prior
to starting.
Before Lighting
Heater should be thoroughly inspected before each use, and by a qualified service person at
least annually.
If relighting a hot heater, always wait at least 5 minutes for gas to dissipate.
Lighting
1. Turn control knob to “OFF” position.
2. Turn on gas at LP gas tank.
3. Push in control knob and rotate to “ON” position. This will
activate the built-in ignitor and light the burner. If necessary,
keep depressing and rotating knob until burner lights.
4. Once burner is lit, hold control knob in for at least 30 seconds
and release.
5. If burner does not stay lit, turn to “OFF” position and wait 5
minutes and repeat steps 2
and 3.
6. If ignitor does not light burner, use a lit match positioned against
the bottom of emitter screen at burner location, and repeat steps
2 and 3.
7. Once burner is lit, rotate knob to desired heating level.
If you experience any ignition problem, turn off the heater and gas
supply, and consult “Troubleshooting”.
Caution: Avoid inhaling fumes emitted from
the heater’s first use. Smoke and odor from the burning of oils used in
manufacturing will appear. Both smoke and odor will dissipate after
approximately 30 minutes. The heater should NOT produce thick black smoke.
X
X
X
X
X
20 lb. LP Gas Tank Valve
Installing LP Gas Tank (continued)
Regualtor Connection