background image

P12

User Manual

7531 

and 

7532

BATTERY CHARGER

Read and understand the contents of this User Manual. It contains important safety, handling, and operational instructions for P12 Battery Chargers.
This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion 
of Blue Sea Systems. To view the most current revision of this publication visit bluesea.com/P12.

Scan for 
additional
product
information

Summary of Contents for 7531

Page 1: ...perational instructions for P12 Battery Chargers This User Manual describes the product mentioned herein at the time of its publication Specifications and performance are subject to change at the disc...

Page 2: ...ation cover there are no user serviceable parts within the battery charger enclosure Contact Blue Sea Systems for servicing Charge only user selectable type batteries other types of batteries may burs...

Page 3: ...anks may finish charging at different rates Once a battery bank has met its unique Absorption parameters the P12 Charger will independently move it into the Pre Float stage Pre Float is the initial st...

Page 4: ...F 30 C 22 F Maximum Storage Temperature 80 C 176 F 80 C 176 F Warranty 5 Year 5 Year Battery Types Flooded Gel AGM TPPL Thin Plate Pure Lead Flooded Gel AGM TPPL Thin Plate Pure Lead Recommended for...

Page 5: ...rewdriver Dielectric Grease Used for Temperature Sensor and the Optional Accessory P12 Remote Display Connections View the MSDS for the Dielectric Grease at bluesea com P12 Temperature Sensor Flying l...

Page 6: ...Wiring Connections Diagram page 10 4 Then remove the AC and DC wire termination strain relief clamps by unfastening the screws AC Connections Strain Relief DC Connections Strain Relief Best practices...

Page 7: ...ach the sensor in the center of the long side of the battery b If multiple batteries are in a battery bank attach sensor in the center between multiple batteries c When external circumstances could cr...

Page 8: ...you may adjust the length of seconds the backlight will remain on b The backlight timer can be adjusted between 5 and 59 seconds It may also be set permanently on or permanently off 15 Press the OK bu...

Page 9: ...ttings by default To disable this factory setting select Charger Setup Menu select Battery and then press the down arrow and select Set Absorb Timers Then press the down arrow four times to view Gener...

Page 10: ...k professional guidance before performing equalization Equalization causes off gassing of harmful chemicals inside of the battery Only perform equalization while the batteries are in a well ventilated...

Page 11: ...ating temperature based on the temperature sensor Read the Temperature Parameters section on page 15 before making any adjustments Options Select Units and temperature parameters to adjust How to Get...

Page 12: ...hout sufficient knowledge is dangerous and can cause personal or property harm If the battery temperature sensor goes outside a designated parameter contact your battery manufacturer for further infor...

Page 13: ...F START ENGINE START SWITCH ON OFF START FUSE FUSE 7520 BATTERY CHARGER LED REMOTE Sold Separately START START HOUSE FUSE FUSE FUSE FUSE DC GROUND OPTIONAL CONNECTION REMOTE DISPLAY START ISOLATION AC...

Page 14: ...as new condition Such repair or replacement will be the sole remedy by Blue Sea Systems under this warranty Any repaired or replacement product will be warranted in accordance with this warranty for t...

Page 15: ...425 Sequoia Drive Bellingham WA 98226 USA p 360 738 8230 p 800 222 7617 USA and Canada Customer Service conductor bluesea com www bluesea com 980025140 Rev 003...