Summary of Contents for E91

Page 1: ...Manuals and Documents Brought to you by Wechillit com Ltd WCI Group House 18 Pride Hill Shrewsbury SY1 1DQ Tel 01743 289418 Fax 01743 289416 Web www wechillit com ...

Page 2: ... Moffat Ltd January 2007 Revision 1 Blue Seal Evolution Series Electric Salamander Electric Salamanders E91 Service Manual ...

Page 3: ... 2007 Revision 1 Blue Seal Evolution Series Electric Salamander ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY WARNING MAKING ALTERATIONS MAY VOID WARRANTIES AND APPROVALS IMPORTANT ...

Page 4: ...ompleteness and those special cases where these settings are required to change this manual gives a full explanation as to how and what effects will result Section Page Number 1 Specifications 1 2 Installation 3 3 Operation 6 3 1 Description of Controls 3 2 Racking 4 Cleaning Maintenance 7 5 Trouble shooting Guide 8 6 Service Procedures 9 6 1 Access 6 2 Replacement 7 Accessories 12 8 Exploded Part...

Page 5: ... Moffat Ltd January 2007 Revision 1 Blue Seal Evolution Series Electric Salamander ...

Page 6: ... 1 Specifications Moffat Ltd January 2007 Revision 1 Blue Seal Evolution Series Electric Salamander External Dimensions Model Numbers Covered in this Specification E91 Electric Salamander Front Side Plan ...

Page 7: ...ries Electric Salamander Salamander Internal Dimensions Rack Size 610mm x 310mm Branding Plate accessory 610mm x 310mm Cooking Area E91 41kg Weight Net Width Depth Height E91 685 mm 330 mm 230 mm at front Voltage 220 240Vac 1P N E Power 240Vac 6 0 kW 25A Electrical Requirements ...

Page 8: ...immediately to the carrier and distributor 3 Check that the following parts have been supplied with the Salamander 4 Report any deficiencies to the distributor who supplied the unit 5 Check that the available electrical supply is correct to that shown on the rating plate located on the front bottom corner of the right hand side panel Location 1 This appliance must be mounted onto a non combustible...

Page 9: ...bove any surface 2 Fit the two black plastic spacers to the top rear corners of the unit Leave them unscrewed by approximately 5 mm 3 Fit the two adjusting screws bolts into the nutserts at the bottom rear corners of the unit These should protrude approximately 30 mm from the rear of the Salamander 4 Lift the Salamander onto the wall bracket lining up the black plastic spacers on the salamander wi...

Page 10: ...ll grommet located at the rear of the unit and connect to the terminals as marked 2 If required the appliance can be connected to two 13 or 15 amp single phase supplies by removing the insulated wire loom between the left and right hand terminal blocks Independent supplies can then be connected to each side 3 The operating voltage of the salamander is stated on the rating plate affixed to the righ...

Page 11: ...ide two independ ently controlled heat zones High speed grilling is provided by the two high speed infrared elements in the ceiling of the grilling compartment The left hand control knob and right hand control knob operate the left side and right side elements respectively independently of each other 3 2 Racking Racking System The Rack System fitted to the Blue Seal Salamander is self supporting w...

Page 12: ...wing instructions Remove the Grease Crumb Tray from the underside of the salamander unit Remove the Branding Plate from the rack If fitted Slide the rack out of the side racks and remove from the unit Remove the left and right hand side racks from the unit by removing the single securing screw from each of the side racks Withdraw the left and right hand side racks from the unit Refit the Racking i...

Page 13: ... works The mains isolating switch on the wall circuit breaker or fuses are off at the power board Incorrect electrical supply Turn on Ensure electrical supply correct One element does not work or One element coil does not work Selector switch on unit faulty Element faulty blown Check switch poles replace if faulty Refer service section 6 2 2 Replace Refer service section 6 2 1 Indicator light does...

Page 14: ... WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY ENSURE GAS SUPPLY IS SWITCHED OFF BEFORE SERVICING ALWAYS CHECK TEST FOR GAS LEAKS AFTER SERVICE REPAIRS ON THE GAS SYSTEM WARNING Section Page no 6 1 Access 10 6 1 1 Control Panel 10 6 1 2 Side Panel 10 6 2 Replacement 10 6 2 1 Element 10 6 2 2 Selector Switch 11 6 2 3 Indicator Light 11 ...

Page 15: ...all of the salamander Take care not to lose the element springs 7 Replace the element and reassemble in reverse order NOTE Correct element resistances 5 Inner Coil 30 ohms 1900W Outer Coil 52 ohms 1100W Figure 6 2 1 6 1 1 Front panel 1 Remove selector knob by pulling firmly away from control panel 2 Undo two screws at the bottom of control panel Drop control down to access components 3 Undo the tw...

Page 16: ...op the control panel down to access components 2 Remove the wires from the rear of the neon 3 From rear push neon through front of panel rotating clockwise 4 Push new neon in from front of panel and reconnect wires 5 Replace control panel Figure 6 2 2b Selector switch 1 Remove the selector knob by pulling firmly away from the control panel 2 Undo the two screws at the bottom of the control panel D...

Page 17: ...7 Accessories Moffat Ltd January 2007 Revision 1 Blue Seal Evolution Series Electric Salamander Salamander rack 017963 Rack handle 013395 Side rack 026093 Branding plate 013418 Wall mounting bracket 026096 ...

Page 18: ...Item Part No Description 1 026096 WALL MOUNTING BRACKET 2 026086 BACK PANEL 3 026090 FLUE END RH 4 026094 SIDE PANEL 5 227476 FRONT COVER 6 227963 NEON ORANGE 7 227394 KNOB BSEAL 6MM 1 2 3 8 005017 CONTROL PANEL ELECTRIC 9 026091 TRAY SUPPORT 10 227960 BLUE SEAL BADGE 11 026089 FLUE END LH 8 1 E91 Main Assembly ...

Page 19: ...emblies Item Part No Description 12 026114 ELEMENT SUPPORT WA 13 013920 SALAMANDER ELEMENT SUPPORT SECURING SCREW 14 026088 ELEMENT 3KW DUAL COIL Ø6 5 15 017682 3 HEAT SWITCH 16 026160 TERMINAL BLOCK 17 026161 CABLE CLAMP 18 026093 SIDE RACK WA SALAMANDER 19 013395 RACK HANDLE 20 227961 SIDE RACK SCREW 21 017963 RACK 22 227950 TROUGH TRAY WA ...

Page 20: ... Schematics Moffat Ltd January 2007 Revision 1 Blue Seal Evolution Series Electric Salamander L1 N E OUTER 1100W 1900W 1100W 1900W OUTER 0 OFF 750W 1 2 1900W 3000W 3 CONTROL SWITCH SETTINGS 4 3 2 P2 P1 4 3 2 P2 P1 ...

Page 21: ...0 Wiring Diagram Moffat Ltd January 2007 Revision 1 Blue Seal Evolution Series Electric Salamander P1 2 4 3 P2 P1 2 4 3 P2 1 1 2 3 4 5 5 6 6 7 8 9 10 10 11 12 13 14 14 15 15 16 17 18 19 19 21 21 20 20 22 22 ...

Page 22: ... QLD 4034 Spare Parts Free Call 1800 337 963 Fax 03 9518 3895 WESTERN AUSTRALIA MOFFAT PTY 67 Howe St Tel 08 9202 6820 Osbourne Park WA 6017 Fax 08 9202 6836 Spare Parts Free Call 1800 337 963 Fax 03 9518 3895 NATIONAL COVERAGE FOR 24 HOUR SERVICE OR MAINTENANCE DIAL FREE CALL 1800 622 216 AUSTRALIA ONLY Canada SERVE CANADA 22 Ashwarren Rd Tel 416 631 0601 Downview Fax 416 631 0315 Ontario M3J1Z5 ...

Page 23: ...ingdom BLUESEAL LTD 67 Gravelly Industrial Park Tel 0121 327 5575 Erdington Fax 0121 327 9711 Birmingham B24 8TQ England United States of America MOFFAT INC 3765 Champion Blvd Winston Salem Tel 1800 551 8795 NC27115 Fax 336 661 9546 NATIONAL COVERAGE FOR SERVICE OR MAINTENANCE DIAL FREE CALL 1800 551 8795 USA ONLY ...