15
Part 6 Gas Conversion
Gas Specifications
- Australia:
- New Zealand:
- United Kingdom:
Appliance Classification:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
- All Other Markets:
NOTE:
*
Measure Burner Operating Pressure at Operating Pressure Test Point (Lower - Out) on Gas Control Valve,
this is to be carried out with Main Burner operating. Refer to information shown in this section for further
details.
Natural Gas (G20)
Propane (G31)
Main Burner Injectors
Ø 1.55mm
Ø0 95mm
Pilot Burner Injectors
0.45 0.30
Pilot Screw Adjustment
Full Out (CCW)
1½ turns out (CCW)
Burner Operating Pressure
0.90 kPa (*)
(9.0 mbar)
2.50 kPa (*)
(25 mbar)
Supply Pressure
20 mbar
37 mbar
Natural Gas
LP Gas (Propane)
Main Burner Injectors
Ø 1.55mm
Ø 0.95mm
Pilot Burner Injectors
0.62 0.35
Pilot Screw Adjustment
Full Out (CCW)
1½ turns out (CCW)
Burner Operating Pressure
0.90 kPa (*)
(9.0 mbar)
2.50 kPa (*)
(25 mbar)
Supply Pressure
1.13 - 2.0 kPa
2.75 - 3.0 kPa
Natural Gas
LP Gas / Butane
Main Burner Injectors
Ø 1.55mm
Ø 0.90mm
Pilot Burner Injectors
0.62 0.35
Pilot Screw Adjustment
Full Out (CCW)
1½ turns out (CCW)
Burner Operating Pressure
0.90 kPa (*)
(9.0 mbar)
2.50 kPa (*)
(25 mbar)
Supply Pressure
1.13 - 2.0 kPa
2.75 - 3.0 kPa
Natural Gas
LP Gas (Propane)
LP Gas / Butane
Town Gas
Main Burner Injectors
Ø 1.55mm
Ø 0.95mm
Ø 0.90mm
Ø 2.30mm
Pilot Burner Injectors
0.62 0.35 0.35 0.75
Pilot Screw Adjustment
Full Out (CCW)
1½ turns out (CCW)
1½ turns out (CCW)
Full Out (CCW)
Burner Operating Pressure
0.90 kPa (*)
(9.0 mbar)
2.50 kPa (*)
(25 mbar)
2.50 kPa (*)
(25 mbar)
0.5 kPa (*)
(5 mbar)
Supply Pressure
1.13 - 2.0 kPa
2.75 - 3.0 kPa
2.75 - 3.0 kPa
0.75 - 1.5 kPa
Summary of Contents for Evolution GT18 Series
Page 19: ......