Part 3 Installation
4. Locate the appliance into its final operating
position and using a spirit level, adjust the legs so
that the unit is level and at the correct height.
5. Connect the gas supply to the appliance.
6. Check all gas connections for leakages using
soapy water or other gas detecting equipment.
7. Check Supply Pressure is as shown in the
‘Specifications’ section, ‘Gas Supply
Requirements’ tables. (Measure at the ‘Supply
Pressure Test Point’ (Upper - IN) on the front of
the gas control valve).
8. Measure Main Burner Operating Pressure at
Operating Pressure Test Point (Lower - Out) on
the Gas Control Valve. Adjust if required, as
shown in the ‘Specifications’ section, ‘Gas
Supply Requirements’ tables.
Refer to the ‘Gas Conversion and Specifications’
section of this manual for further details.
9.
Please note that the pilot flame size is factory set
and paint sealed
. Check that the pilot covers
the thermocouple. If the pilot needs adjusting,
this should be carried out by a qualified service
agent.
Assembly
This model is delivered completely assembled.
Ensure that the legs are securely attached.
NOTE:
This appliance is fitted with adjustable feet to enable
the appliance to be positioned securely and level.
This should be carried out on completion of the gas
connection. Refer to the 'Gas Connection' section.
Gas Connection
NOTE:
ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A
QUALIFIED SERVICE PERSON.
1. BLUE SEAL Model Fryers do not require an
electrical connection, they function totally on
the gas supply only.
2. It is essential that the gas supply is correct for the
appliance to be installed and that adequate
supply pressure and volume are available. The
following checks should therefore be made
before installation:-
a.
The Gas Type
the appliance has been
supplied for is shown on coloured stickers
located above the gas entry point and next
to the rating plate. Check that this is correct
for the gas supply the appliance is being
installed for. The gas conversion procedure is
detailed in the Service Manual.
b.
Supply Pressure
required for this appliance is
shown in the “Specifications” section of this
manual. Check the gas supply to ensure that
adequate supply pressure exists.
c.
Input Rate
of this appliance is also stated on
the Rating Plate fitted to the inside of the
access door and in the “Specifications”
section of this manual. The input rate should
be checked against the available gas supply
line capacity.
Particular note should be
taken if the appliance is being added to an
existing installation.
NOTE:
It is important that adequately sized piping runs
directly to the connection joint on the appliance,
with as few tees and elbows as possible to give
maximum supply volume.
3. A suitable joining compound which resists the
breakdown action of LPG must be used on
every gas line connection, unless compression
fittings are used.
The connection to the appliance is
3
/
4
” BSP male.
NOTE:
A Manual Isolation Valve must be fitted to the
individual appliance supply line.
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.